Technical Specifications - Zehnder Rittling ComfoAir 350 Basic Series Installer Manual

Table of Contents

Advertisement

2.2

Technical specifications

Position
Low Setting
Medium Setting
High Setting
Maximum
Position
Low Setting
Medium Setting
High Setting
Maximum
Power supply
Cos.phi
Position
Low Setting
Medium Setting
High Setting
Maximum
Position
Low Setting
Medium Setting
High Setting
Maximum
EN - 4
ComfoAir 350 nL (normal air volumes)
Ventilation capacity
100 m
/h at 20 Pa
3
150 m
/h at 65 Pa
3
225 m
/h at 150 Pa
3
325 m
/h at 235 Pa
3
Ventilation capacity
100 m
/h at 20 Pa
3
150 m
/h at 65 Pa
3
225 m
/h at 150 Pa
3
325 m
/h at 235 Pa
3
Electricity
Supply fan noise level (at 0 m)
Ventilation capacity
100 m
/h at 20 Pa
3
150 m
/h at 65 Pa
3
225 m
/h at 150 Pa
3
325 m
/h at 235 Pa
3
Exhaust fan noise level (at 0 m)
Ventilation capacity
100 m
/h at 20 Pa
3
150 m
/h at 65 Pa
3
225 m
/h at 150 Pa
3
325 m
/h at 235 Pa
3
Power
21 W
44 W
105 W
243 W
Current
0.17 A
0.35 A
0.81 A
1.77 A
230/50 V/Hz
0,50 - 0,60
Sound power
49 dB(A)
59 dB(A)
70 dB(A)
75 dB(A)
Sound power
43 dB(A)
48 dB(A)
55 dB(A)
61 dB(A)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comfoair 350 hlComfoair 350 nl