Visca Camera-Issued Messages - Sony HD 3CMOS BRC-Z700 Command List

Hd 3cmos color video camera
Table of Contents

Advertisement

VISCA Camera-Issued Messages

ACK/Completion Messages
Command
ACK
Completion
z = Device address + 8
Error Messages
Command
Syntax Error
Command Buffer Full
Command Canceled
No Socket
Command Not Executable
Network Change Message
Command
Network Change
8
Command Message
Comments
z0 4y FF
Returned when the command is accepted.
(y: Socket No.)
z0 5y FF
Returned when the command has been executed.
(y: Socket No.)
Command Message
Comments
z0 60 02 FF
Returned when the command format is different or when a command with
illegal command parameters is accepted.
z0 60 03 FF
Could not accept a command that is received while two commands are
currently being executed (two sockets have been used).
z0 6y 04 FF
Returned when a command which is being executed in a socket specified by
(y: Socket No.)
the cancel command is canceled. The completion message for the command
is not returned.
z0 6y 05 FF
Returned when no command is executed in a socket specified by the cancel
(y: Socket No.)
command, or when an invalid socket number is specified.
z0 6y 41 FF
Returned when a command cannot be executed due to current conditions.
(y: Socket No.)
For example, when a command for controlling the manual focus is received
during the auto focus mode.
Command Message
Comments
z0 38 FF
Issued when power is supplied to the camera.