Download Print this page
Carrier 42TW Series Installation, Start-Up And Service Instructions Manual

Carrier 42TW Series Installation, Start-Up And Service Instructions Manual

Chilled water fan coil unit with remote control (50/60 hz)

Advertisement

Quick Links

REMOTE CONTROL
Fig. 1 - 42TW Unit
ELECTRIC SHOCK HAZARD To avoid the possibility of electrical shock, open and tag all
service switches before installing this equipment.
Insta
llation,
Start-
Se
ervice I
Instruct
CONTROL BOARD
WARNING
- 1 -
Up
and
tions
SAFETY CONSIDERATIONS
Installation
and
servicing
equipment can be hazardous due to system
pressure and electrical components. Only trained
and qualified service personnel should install,
repair, or service air conditioning equipment.
Untrained
personnel
maintenance functions of cleaning coils and filters
and replacing filters.
All other operations should be performed by trained
service
personnel
When
conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and
other safety precautions that may apply.
Follow all safety codes. Wear safety glasses and
work gloves. Use quenching cloth for un-brazing
operations. Have fire extinguishers available for all
brazing operations.
CONTENTS
Page
Safety Consideration
1
Introduction
2
Receiving
2
Inspection
2
Protection
2
Preliminary Check
2
Physical Data
2
Sound Data
4
Fan Performance Data
5
Base Unit Dimensions
6
Prepare Jobsite
7
Identify and Prepare Units
7
Unit Configuration
7
Rigging and Unpacking
7
Installation
7
42TW/TD
Chilled Water
Fan Coil unit
with Remote Control
(50/60 Hz)
air-conditioning
can
perform
basic
working
on
air-
Placing unit in position
Making Piping Connections
Electrical Heater Option
Test and Insulate
Make Electrical Connections
Make Duct Connections
Make Final Preparation
Control Board & Remote control
Typical wiring digram
Start-up
Service
Start-up Checklist
Page
7
7
8
8
8
8
8
9,10
11,12
13
13
14

Advertisement

loading

Summary of Contents for Carrier 42TW Series

  • Page 1 42TW/TD Chilled Water Fan Coil unit with Remote Control (50/60 Hz) Insta llation, Start- ervice I Instruct tions SAFETY CONSIDERATIONS Installation servicing air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air conditioning equipment.
  • Page 2: Preliminary Check

    This document contains general installation damaged, file claim with transportation instructions for the 42TW unit Fan Coils. Refer company and notify Carrier immediately. to the unit-wiring diagram installed on the blower housing specific manufacturer PROTECTION literature for any other type of factory-mounted Protection unit from damage caused by job controls.
  • Page 3 Table.2 - Physical Data - 42TW4,42TD4 – 2 Pipe System Size Model 42TW4 Model 42TD 4 CFM* 1065 1247 1416 Cooling Capacity (kw)* 12.7 15.7 17.6 Colling Capacity (kbtuh) 13.0 21.0 26.3 30.8 33.7 43.3 53.6 60.1 0.69 0.71 0.69 0.69 0.69 0.68...
  • Page 4 Table.4 a - POWER CONSUMPTION 42TW,42TD 3ROW @ 0 Pa ESP @ 25 Pa ESP @ 50 Pa ESP 42TW,42TD 3 Row Amps 0.40 0.35 0.30 0.34 0.28 0.24 0.30 0.25 0.20 Watts Amps 0.45 0.40 0.35 0.37 0.32 0.27 0.33 0.28 0.22...
  • Page 5 Table.6 a - Fan Performance 42TW - 3 - SI 42TW3 Air Flow (m /hr) Ex. Static Pres. Pa 12.5 37.5 Unit Size 1005 1176 1132 1088 1024 1325 1174 1031 1284 1090 1243 1006 1158 1500 1285 1120 1420 1178 1011 1340...
  • Page 7 PREPARE JOSITE FOR UNIT INSTALLATION against available power supply. For special installation, To save time and to reduce the possibility of consult local building and electrical codes. costly errors, set up a complete sample installation in a typical room at jobsite. Check all INSTALLATION critical dimensions such as pipe, wire, and duct PLACING UNIT IN POSITION...
  • Page 8 3 ft of shipping damage or mishandling. If leaks are ductwork. Install ductwork, accessory grilles found, notify a Carrier representative before and plenums so that they do not restrict initiating any repairs. Release trapped air from access to filter.
  • Page 9: Split System Description

    Controller For Ducted Fan Coil Units Features The controller is used to control air cooled ducted split unit, supports the following functions: - Modes: Cool, Dry, Fan, Heat - Indoor fan speed: Auto, High, Medium, Low - Sleep mode - Compressor protections: Comp 3 minutes restart protection Indoor coil anti-freeze Room sensor and indoor coil sensor failure monitoring...
  • Page 10 Cool Mode If the room temperature is higher than the setting, the compressor will automatically turn on provide a cooling effect. On the hand, if the room temperature is lower than the setting, the compressor will automatically turn off to stop cooling operation. If indoor fan is programed to be turned off with comp signal, it will turn off once comp is cut off Heat Mode: If the room temperature is lower than the setting, the Electric heater will automatically turn on to provide a heating effect.
  • Page 11 WIRING SCHEMATIC 42TW/TD COOL/HEAT -11-...
  • Page 12 WIRING SCHEMATIC 42TW/TD COOL/HEAT WITHOUT CONTROL -12-...
  • Page 13 START-UP Fan assembly may be removed from its 42TW unit is designed to operate in hot and tracks if unit has a long conduit lead. Use a humid conditions without condensation stiff brush or vacuum to remove dirt and problem because of the rubber insulated debris from scroll.Wipe all fan surfaces with a drain pan.
  • Page 14 START-UP CHECKLIST FOR 42TW SERIES FAN COIL UNIT I. Project Information Job Name _______________________________________________________________________ Address ________________________________________________________________________ City ______________________________________________State __________ Zip __________ Installing Contractor _______________________________________________________________ Sales Office _____________________________________________________________________ Start-up Performed By _____________________________________________________________ INSPECTION, INSTALLATION, & START-UP CHECKLIST ITEM COMPLETE ITEM COMPLETE Receiving &...
  • Page 15 NOTES...
  • Page 16 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations 42TW/TD - 05 - IOM 2015...

This manual is also suitable for:

42td series