Installing the refrigeration
appliance in a run of kitchen
units
Risk of fire and damage due to
insufficient ventilation.
If the refrigeration appliance is not
ventilated sufficiently, the
compressor will run more frequently
and for longer periods. This will
result in increased energy
consumption and a higher operating
temperature for the compressor. This
may, in turn, cause damage to the
compressor.
Please ensure that there is adequate
ventilation around the refrigeration
appliance.
It is essential to observe the
ventilation gaps given. The
ventilation gaps must not be covered
or blocked in any way.
 Top box
 Refrigeration appliance
 Housing unit
 Wall
* The appliance depth is increased by
approx. 35 mm for refrigeration
appliances with wall spacers fitted.
The refrigeration appliance can be built
into a kitchen run and installed directly
next to a kitchen furniture housing unit.
The appliance front must protrude in
front of furniture fronts by at least
65 mm. This enables the doors to be
opened and shut without being
obstructed. To match the height of the
rest of the kitchen, the refrigeration
appliance can be fitted with a suitable
top box .
When installed next to a wall , a
distance of at least 40 mm must be
maintained on the hinge side between
the wall  and the refrigeration
appliance .