Technical Data - LinMot S01-72/1000 Installation Manual

Power range 1000 w
Table of Contents

Advertisement

Installation Guide Power Supply

3 Technical Data

Input
Input voltage range
Power frequency
Efficiency
Input current limitation
Internal fuse
External branch circuit
Output
Preset range Vo
Max. output power
Powerboost > 0.5s - 2s
Powerboost < 0.5s
Operation indicator
Ripple
Noise voltage
Temperature coefficient
Switch on / switch off
Start-up delay
Rise time
Back feeding voltage
Serial connection
Parallel connection
Regelung
Line regulation
Load regulation
Response time
Protection and Controlling
Overvoltage protection (OVP)
Current limitation
Overtemperature
Mains buffering
Relay contact
Control signal OFF
NTI AG / LinMot
< 35A
typ. in cold state, < 70A
peak
16A (IEC), 20A (USA) necessary
factory setting Vo
boost break necessary, see diagram in chapter 7
no boost break necessary, but the boost time in the last 4s may not be
longer as 2s, otherwise a boost break 1min is necessary (boostbreak
<25ms will be not recognized)
green LED for Vo, red LED for error
No Vo overshoot (soft-start)
20ms typ./155ms typ.bei 50.000 μF Last
yes, max. 2 identical power supplies
yes, max. 3 identical power supplies
< 0.3% for Vo at Ue
< 0,5% for Vo at Io 0 - 100% single operation
< 3% for Vo at Io 0 - 100% parallel operation
see diagramm, output permanent short-circuit proof
Switches off if inside temperature becomes
to high, reconnection with hysteresis
11 ms typ. in normal operation
Relay contact (<80V/0.2A), changing
at Vo < 37 / 52V from OK to FAIL
external switch-off with 5 - 63VDC/5mA
Power range 1000 W
S01-72/1000
AC 3 x 340-550V
50/60Hz
typ. 91,5%
peak
3 x 6.3AT
56 - 80VDC
± 0,15/0,2V
nom
1000W
40mVss typ.
200mVss typ.
≤ 0,025% / K
250 ms typ.
approx. 100VDC
- Ue
min
typ. 1ms at Io 20 - 80%
approx. 87V
automatical repeating
or switch from Vo
ENG
in hot state
max
min
Page 5 / 12