Cleaner Maintenance; User Checklist - Hoover Khross User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Allergen Remover Mini Turbo Nozzle* – Use the mini turbo nozzle on stairs or for deep
cleaning on textile surfaces and other hard to clean areas. Particularly suitable for allergen
removal. [X]
IMPORTANT: Do not use the Mini Turbo nozzles on rugs with long fringes, animal hides and
carpet pile deeper than 15mm. Do not keep the nozzle stationary while the brush is rotating.

CLEANER MAINTENANCE

Emptying the Dust Container
When the dust reaches the max level indicator in the container empty the dust container.
IMPORTANT: To maintain optimum performance do not allow the dust to sit higher than
the max level.
1. Turn off the cleaner pressing on/off pedal and unplug the power cable. [8]
2. Press the dust container release button and remove the dust container assembly from
the cleaner. [12]
3. Hold the dust container with one hand and press the dust container empty button to
empty the dust. [13]
4. Close the dust container flap and refit to the main body.
Cleaning the washable filters
The cleaner is fitted with pre-motor filter and exhaust filter. To maintain optimum cleaning
performance, regularly remove the filters and tap against the side of the dust container to
release dust. The filters should be washed every 5 cassette empties or when the filters have
excessive dust level.
IMPORTANT: All bagless cleaners require regular filter cleaning. Failure to clean your
filters may result in air blockage, overheating and product failure. This may invalidate your
guarantee.
IMPORTANT: Regularly check and maintain the filters.
IMPORTANT: Always ensure the the filters are fully dry before use.
To access the pre-motor filter:
1. Remove the dust container from the cleaner by pressing the dust container release
button. [12]
2. Hold the dust container with one hand and remove the dust container cover by rotating
anti-clockwise with the other hand. [14]
3. Remove the pre-motor filter assembly from dust container assembly. [15]
4. Gently tap and wash the pre-motor filter. Do not use hot water or detergents. Remove
excess water from the filter and leave to dry fully before re-using. [20,21]
5. Reassemble the pre-motor filter assembly once fully dry and refit to the cleaner.
To access the exhaust filter:
1. Unclip the exhaust filter cover from the rear of the cleaner main body. [18]
2. Remove the exhaust filter from the rear of the cleaner. [19]
3. Gently tap and wash the filter using warm water. Do not use hot water or detergents.
Remove excess water from the filter and leave to dry fully before re-using. [20,21]
4. Refit the exhaust filter to the rear of the cleaner once fully dry and refit the exhaust
filter cover.
IMPORTANT: Do not use the product without the filter pack fitted.
*Certain Models Only
** Certain models only, nozzles may vary according to model
Cleaning the dust container / separation unit
This cleaner uses a separation system unique to Hoover. If necessary, the separation unit
can be disassembled from the dust container and cleaned.
1. Press the dust container release button and remove the dust container assembly from
the cleaner. [12]
2. Hold the dust container with one hand and remove the dust container cover by rotating
anti-clockwise with the other hand. [14]
3. Remove pre-motor filter assembly from the dust container assembly. And then remove
the multi-cyclone separation unit from the dust container by pulling it. [15,16]
4. If necessary, use a cloth to remove excessive dust from the multi-cyclone separation unit
surface. [17]
5. If necessary rinse the dust container with lukewarm water. Wash internal surfaces of
the dust container with water only. DO NOT use soap detergents to wash the internals
of the dust container.
6. Reassemble the internal and the pre-motor filter to the dust container.
7. Reassemble the dust container cover to the dust container. Refit the dust container to
the cleaner main body.
Removing a blockage
1. Check if the dust container is full. If so refer to 'Emptying the dust container' .
2. If the dust container is empty but suction is still low:
A. Do the filters need cleaning? If so refer to 'Cleaning the washable filters' .
B.
Check if there is any other blockage in the system - Use a rod or pole to remove any
blockage from the extension tube or flexible hose.
C.
Check if pre-motor filter is fitted.
D.
Check if the separation unit needs to be cleaned. Refer to 'Cleaning the separation unit' .

USER CHECKLIST

Should you have a problem with the product, complete this simple user checklist before
calling your local Hoover service.
• Is there a working electricity supply to the cleaner? Please check with another electrical
appliance.
• Is the dust container over-filled? Please refer to 'Cleaner Maintenance' .
• Is the filter blocked? Please refer to 'Cleaner Maintenance' .
• Is the hose or nozzle blocked? Please refer to 'Removing a blockage from the system' .
• Has the cleaner overheated? If so, it will take approximately 30 minutes to automatically reset.
3
GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents