Problem
The container being
used is not recognised
by the automatic spout
adjustment repeatedly.
The central spout
moves to the rim of the
cup or glass and
triggers the cup
protection cut-out.
The cup protection cut-
out is not working. The
central spout moves to
the rim of the cleaning
container and becomes
wedged against the rim.
86
Cause and remedy
The container is unsuitable for the cup sensing
system.
 Use other cups or glasses that can be recognised
by the automatic spout adjustment function.
There is a fault with the automatic spout adjustment.
 Switch the machine off with the On/Off sensor .
Wait for approx. 2 minutes before switching it back
on again.
 Use another cup or glass and make a drink.
 If the cup protection cut-out is triggered again or
the central spout moves to the rim of the cup or
glass again, contact Miele.
If the cleaning container is very close to or touching
the rear panel, the automatic spout adjustment will
not detect the rim properly.
 Move the cleaning container slightly further
forwards.