SUPPLEMENTAL MATERIAL
In
Figure
15, two ports from the VIC 1340 are channeled to 2304 Fabric Extender A and two are channeled
to 2304 Fabric Extender B. Adapter slot 2 is empty. The VIC 1380 installed in adapter slot 3 connects four
ports from a native 40G interface to each of the Fabric Extenders. The result is 60 Gb of bandwidth to each
Fabric Extender.
Figure 15
VIC 1340 and VIC 1380 (adapter slot 2 empty)
2304 Fabric
Extender A
Port Group A
In
Figure
16, two ports from the VIC 1240 are channeled to 2304 Fabric Extender A and two are channeled
to 2304 Fabric Extender B. The Port Expander Card installed in adapter slot 2 acts as a pass-through device,
channeling two ports to each of the Fabric Extenders. In addition, the VIC 1280 channels four ports to each
Fabric Extender. The result is 80 Gb of bandwidth to each Fabric Extender.
Figure 16
VIC 1240, Port Expander in Adapter Slot 2, and VIC 1280 in Adapter Slot 3
2304XP Fabric
Extender A
Port Group A
Port Group B
VIC 1280 Adapter
adapter slot #3
PCIe x16
CPU 2
50
Port Group B
EMPTY
No Adapter
VIC 1380 Adapter
Installed
adapter slot #3
adapter slot #2
PCIe x16
CPU 2
CPU4
Port Expander Adapter
adapter slot #2
If a Port Expander is installed in slot #2,
CPU4
CPU4 is optional. If a Storage Accelerator
is installed in slot #2, CPU4 is required.
Port Group A
Port Group B
VIC 1340 Adapter
adapter slot #1 for VIC 1340
If a Port Expander is installed in slot #2,
CPU4 is optional. If a Storage Accelerator
is installed in slot #2, CPU4 is required.
Port Group A
Port Group B
10G KR
10G KR
10G KR
10G KR
VIC 1240 Adapter
adapter slot #1 for VIC 1240
PCIe x16
CPU 1
2304 Fabric
Extender B
PCIe x16
CPU 1
2304XP Fabric
Extender B