CONFIGURING the SERVER
Table 10 Supported Hot Plug Drives (continued)
Product ID (PID)
6 Gbps Drives
UCS-SD16TBKS4-EV
UCS-SD480GBKS4-EV
UCS-SD240GBKS4-EV
UCS-SD120GBKS4-EV
Supported Configurations
Select up to 4 of the drives listed in
bays selected in
Notes
When creating a RAID volume, mixing different capacity drives causes the system to use the
lowest-capacity drive.
Mixing of drive types is supported, but performance may be impacted.
Multiple RAID volumes are supported. RAID volumes should use the same media type.
20
PID Description
1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510)
480 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510)
240 GB 2.5 inch Enterprise Value 6G SATA SSD
120 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510)
CHOOSE RAID CONTROLLER AND DISK DRIVE BAYS on page
Table
10. This is dependent on the number of drive
Drive
Capacity
Type
SATA
1.6 TB
SATA
480 GB
SATA
240 GB
SATA
120 GB