Download Print this page

Emerson LX Series User Manual page 42

Brushless servo drives, amplifier/motor

Advertisement

4.3.3 Simulated Encoder Resolution
SW4 sets the simulated encoder resolution according to the following table. The default
position is 512 lines per revolution.
Table 4-C – Encoder Step/Revolution
SW4/1
0
0
1
1
4.4
Configuration Tables
This section covers the adjustments that are necessary when using a motor not covered
under the DX motor setup chart in Section 4.2.
4.4.1 Full Scale Speed
SW1/1 sets the full scale speed to match the control loop to the motor rated maximum
speed.
ON = 3000 RPM (default)
OFF = 6000 RPM
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
SW4/2
ENCODER STEP/REVOLUTION
0
1
0
1
OFF = 0 ON = 1
1024
512
256
128
Section 4– Page 4

Advertisement

loading