Operation
Check the start switch, the engine stop
switch, and the engine shut-off switch for
proper operation.
Push the start switch to start the engine. As
soon as the engine starts running, push the
engine stop switch to verify that the engine
stops immediately. Restart the engine, and
then pull the engine shut-off cord (lanyard) to
remove the clip from the engine shut-off
switch to verify that the engine stops immedi-
ately. (See pages 19 to 20 for information on
proper operation of the start switch, the en-
gine stop switch, and the engine shut-off
switch.)
1 Engine shut-off switch
2 Start switch
3 Engine shut-off cord (lanyard)
4 Engine stop switch
5 Clip
EJU32680
Cooling water pilot outlet
Check that water comes out from the cooling
water pilot outlet while the engine is running
31
and the watercraft is in the water. (See page
20 for more information.)