Absolute Maximum Ratings

Item
Applied voltage
Input voltage
Output sink current
Static electricity (Human body model)
Static electricity (Machine model)
Characteristics
Item
Temperature accuracy
Human detection distance
Viewing angle
Optical axis gap
Current consumption
Setup time
Note: ✽ 1 To have more than 4 °C
7.2 °F
Detection object size: 700 × 250 mm
Performance
Item
Number of pixel
External interface
Frame rate
✽1
Operating mode
Output mode
Calculate mode
Temperature output resolution
Number of sensor address
Thermistor output temperature range
Thermistor output resolution
Note: ✽ 1 Normal Mode : normal operation mode; Sleep Mode: detection is off (output and data reading not possible); Standby Mode: 1 frame measuring
intermittently every 10 or 60 sec.

Internal Circuit

3.3 V.DC or 5 V.DC
Capacitor
10 μF
GND
✽ INT terminal 4 normally has same voltage as VDD. When interrupting, same as GND (0V)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Infrared Array Sensor Grid-EYE (AMG88)
Absolute maximum ratings
−0.3 V.DC to 6.5 V.DC
−0.3 V.DC to VDD +0.3 V.DC
−10 mA to 10 mA
Typical ±2.5 °C
✽1
of temperature difference from background
27.559 × 9.843 inch
(Assumable human body size)
Infrared array sensor
Sensor chip
VDD
9
Selector
Gain
amp
ADC
GND
6
Thermistor
1 kV
200 V
Performance
High gain
±4.5 °F
Max. 5 m
16.404 ft
Typical 60 °
Within Typical ±5.6 °
Typical 4.5 mA (normal mode)
Typical 0.2 mA (sleep mode)
Typical 0.8 mA (stand-by mode)
Typical 50 ms (Time to enable communication after setup)
Typical 15 s (Time to stabilize output after setup)
Performance
64 (Vertical 8 × Horizontal 8 Matrix)
2
I
C (fast mode)
Typical 10 frames/sec or 1 frame/sec
Normal
Sleep
Stand-by (10 sec or 60 sec intermittence)
Temperature output
No moving average or Twice moving average
0.25 °C
2
2 (I
C slave address)
−20 °C to 80 °C –4 °F to +176 °F
0.0625 °C
ROM
I
2
C I/F
Control
Terminal
VDD
SCL, SDA, AD_SELECT
INT, SDA
All terminals
All terminals
Low gain
Typical ±3.0 °C
±5.4 °F
SDA
2
SCL
3
AD_SELECT
5
INT
4
00