Festo DGC-HD Series Operating Instructions Manual

Festo DGC-HD Series Operating Instructions Manual

Linear drive
Hide thumbs Also See for DGC-HD Series:

Advertisement

Quick Links

Linear drive
DGC-HD
(en) Operating
instructions
8074748
2017-10a
[8074750]

Advertisement

Table of Contents
loading

Summary of Contents for Festo DGC-HD Series

  • Page 1 Linear drive DGC-HD (en) Operating instructions 8074748 2017-10a [8074750]...
  • Page 2 ............Festo – DGC-HD – 2017-10a...
  • Page 3: Table Of Contents

    ............Festo – DGC-HD – 2017-10a English...
  • Page 4: Control Sections And Connections

    DGC-HD Documentation on the product For all available product documentation è www.festo.com/pk Control sections and connections Shock absorbers (2x) Supply ports Guide rail (2x) Surface for profile mounting Lubrication hole for bearing guide (4x) Slot for slot nut mounting and accessories...
  • Page 5: Function And Application

    For transport, the conveyors must be positioned at the permissible support spacing (support spacing è 12 characteristic curves). • Make sure storage conditions are as follows: – short storage times – cool, dry, well-shaded, corrosion-resistant locations. Festo – DGC-HD – 2017-10a English...
  • Page 6: Requirements For Product Use

    • Take the tolerance of the tightening torques into account. Unless otherwise specified, the tolerance is ±20 %. • Make sure there is a supply of correctly prepared compressed air (è Technical data chapter). Festo – DGC-HD – 2017-10a English...
  • Page 7: Installation

    0.5 mm). For gantry applications, parallel align­ ment of the axes is additionally required. For additional informa­ tion, please contact your local Festo Service. Fig. 4 • Place the DGC-HD so that all the control sections are accessible.
  • Page 8 DGC-HD • Fasten the DGC-HD. • Please select the corresponding accessories from our catalogue (è www.festo.com/catalogue). Profile mounting Slot nut mounting Profile mounting in the slot aA of the mounting Slot nut mounting in slot aA. surface 8 When tilted, the slot nuts slide into the slot at each position of the profile Tab.
  • Page 9: Installation Of The Effective Load

    Tab. 3 Effective loads with own guide: • Adjust the guides of the effective load and of the DGC-HD so that they are exactly parallel. This avoids overloading of the guide and increased wear. Festo – DGC-HD – 2017-10a English...
  • Page 10: Installation Of Accessories

    Tab. 4 To protect the end positions: • Use emergency buffer or shock absorber (è Assembly instructions of the accessory used). To avoid contamination: • Use slot covers in all unused grooves. Festo – DGC-HD – 2017-10a English...
  • Page 11: Pneumatic Installation

    End position cover side End position, connection side Movement to the cover side Movement to the connection side Fig. 9 For setting the speed: • Rotate the one-way flow control valves GRLA into the supply ports. Festo – DGC-HD – 2017-10a English...
  • Page 12: Commissioning

    4. Check whether the speed of the slide has to be modified. 5. Open up the one-way flow control valves slowly until the desired slide speed is reached. As intended, the slide should reach the end position without striking hard against it or bouncing back. Festo – DGC-HD – 2017-10a English...
  • Page 13 Distance d [mm] 27.3 … 52.3 31 … 56 41 … 76 Tightening torque [Nm] Tab. 5 If the effective load or dynamic response is modified: • Check whether other cushioning components are required. Festo – DGC-HD – 2017-10a English...
  • Page 14: Service And Maintenance

    (è Fig. 13) As required Grease Roller bearing grease 1) Or if there is no longer a layer of grease on the component 2) Grease gun, blast pipes and grease (è 9 Accessories) Tab. 6 Festo – DGC-HD – 2017-10a English...
  • Page 15: Repair

    • Recommendation: Send the DGC-HD to our repair service. This way the required fine tuning and tests will be taken into special consideration. • Information about spare parts and accessories can be found at: (è www.festo.com/spareparts). To replace cushioning elements: •...
  • Page 16: Troubleshooting

    Heavy leakage Seal worn Replace worn parts: – yourself with set of wearing parts – send product to Festo for repairs Sealing band pressed/ When the linear drive is unpressurized, move the sucked in slide twice manually through the entire stroke...
  • Page 17: Technical Data

    Wiper seal Seals NBR, TPE-U Weight 0-stroke [kg] 3.987 7.509 20.469 per 10 mm stroke [kg] 0.071 0.105 0.199 1) The following tool is available for sizing: sizing software “DGC-QuickCalc” (è www.festo.com/sp) Tab. 9 Festo – DGC-HD – 2017-10a English...
  • Page 18: Characteristic Curves

    DGC-HD Characteristic curves Maximum permissible support span l as a function of the force F DGC-18-HD DGC-25-HD DGC-40-HD DGC-18-HD DGC-25-HD DGC-40-HD Fig. 15 Festo – DGC-HD – 2017-10a English...
  • Page 19 DGC-HD Festo – DGC-HD – 2017-10a...
  • Page 20 Copyright: Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany Phone: +49 711 347-0 Fax: +49 711 347-2144 Reproduction, distribution or sale of this document or communica­ E-mail: tion of its contents to others without express authorization is service_international@festo.com...

This manual is also suitable for:

Dgc-18-hdDgc-25-hdDgc-40-hd

Table of Contents