6.23. Remove the stand brackets
and rear mounting metals
1. Remove the plasma panel section from the servicing stand
and lay on a fiat surface such as a table (covered) with the
plasma panel surface facing downward.
2. Remove the stand brackets (left, right) fastening screws (×3
each).
3. Remove the rear mounting metals (left, right) fastening
screws (×4
each).
4. Remove the stand brackets and rear mounting metals.
5. Remove the fastening screws (×4
6. Remove the stand brackets from rear mounting metals.
6.24. Remove the C4-Board
1. Remove the flexible cables holder fastening screws (×6
2. Disconnect the flexible cables (CB9, CB10 and CB11).
3. Disconnect the flexible cable (C43).
4. Disconnect the couplers (C42 and C44).
5. Remove the screws (×5
6.25. Remove the C5-Board
1. Remove the flexible cables holder fastening screws (×8
2. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).
3. Disconnect the flexible cables (C50, C51, C52 and C53).
4. Remove the screws (×6
each).
17
)
) and remove the C4-Board.
).
) and remove the C5-Board.
TH-58PX600U