Download Print this page

Daikin FVXS35FV1B Service Manual page 20

2.5/3.5/4.5/5.0 kw class, 9000/12000/15000/18000 btu/h class removal procedure
Hide thumbs Also See for FVXS35FV1B:

Advertisement

Fan Rotor / Fan Motor
Step
2
Remove the 3 screws,
and then the fan motor
cover.
3
Unfasten the 2 hooks to
remove the harness
retainer.
4
Remove the fan motor.
3. Remove the casing.
1
Remove the 3 screws
and unfasten the 2
hooks to remove the
upper casing.
2
Remove the 4 screws
and unfasten the 4
hooks to remove the 2
casings.
18
Procedure
Fan motor
cover
Harness retainer
Fan motor
Hook
Hook
Casing
Some models have the
earth/ground wire attached
with the fan motor cover
screw.
When reassembling, make
sure the earth/ground wire is
within the fan motor cover
line.
Earth/ground
wire
(R24280)
There is no hook around the
fan motor. Be careful not to
drop it when the harness
retainer is removed.
Hook
(R22192)
Press the 2 hooks toward
Upper casing
the back side and remove
the casing.
(R24281)
Press the 4 hooks toward
the back side and remove
the 2 casings.
Hook
(R22194)
Si061262EE
Points
(R22753)
Removal Procedure

Hide quick links:

Advertisement