Download Print this page

Daikin FVXS35FV1B Service Manual page 16

2.5/3.5/4.5/5.0 kw class, 9000/12000/15000/18000 btu/h class removal procedure
Hide thumbs Also See for FVXS35FV1B:

Advertisement

Vertical Blade ASSYs
Step
5
Remove the 2 screws
and pull out the swing
motor.
6
Disconnect the
connector and remove
the swing motor.
2. Remove the vertical blade
ASSYs (lower).
1
Remove the 2 screws.
2
Remove the drain hose.
3
Release the lower air
outlet motor harness
from the hook.
14
Procedure
Swing motor
Lower air outlet motor harness
Drain hose
Points
(R22174)
(R22175)
(R22176)
Place a plastic sheet around
the drain pan to prevent
wetting the floor with
remaining drain.
Hook
If embedded in the wall, the
drain hose can be
disconnected from the back
of the indoor unit.
(R22177)
Removal Procedure
Si061262EE

Hide quick links:

Advertisement

loading