WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
DANGER
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
HOMEOWNER'S MANUAL
HOT GLASS
WILL
CAUSE BURNS.
DO NOT TOUCH
GLASS
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.
Empire Comfort Systems Inc. • Belleville, Illinois
DIRECT VENT ZERO CLEARANCE
GAS FIREPLACE HEATER SERIES:
DVCT36CFP95N-1
DVCT36CFP95P-1
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
DVCT40CFP95N-1
DVCT40CFP95P-1
GAS-FIRED
UL FILE NO. MH30033
This fireplace is design
certified in accordance
with American National
Standard/CSA Standard
ANSI Z21.88/CSA 2.33
and by Underwriters
Laboratories as a Direct
Vent Gas Fireplace
Heater and shall be
installed according to
these instructions.
Page 1

Advertisement

loading

Summary of Contents for Empire DVCT40CFP95N-1

  • Page 1 Vent Gas Fireplace hot viewing glass is provided with this appliance and shall Heater and shall be be installed for the protection of children and other at-risk installed according to individuals. these instructions. Empire Comfort Systems Inc. • Belleville, Illinois Page 1...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE PAGE MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS MAINTENANCE AND SERVICE 11-12 IMPORTANT SAFETY INFORMATION SAFETY INFORMATION FOR USERS OF LP GAS REQUIREMENTS FOR MASSACHUSETTS WARRANTY BACK COVER COMBUSTIBLE MATERIAL WARNING Do not attach combustible material above your fireplace. This is a fire hazard.
  • Page 3: Multifunction Remote Operating Instructions

    MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Figure 2 Technical Data Remote Control Supply voltage 4.5 V (three 1.5 V AAA batteries) Ambient temperature ratings 0-50°C (32 - 122°F) Radio frequency 315 MHz WARNING THE TRANSMITTER AND RECEIVER ARE RADIO FRE- QUENCY DEVICES. PLACING THE RECEIVER IN OR NEAR METAL MAY SEVERELY REDUCE THE SIGNAL RANGE.
  • Page 4 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Initializing the System for the First Time With the batteries already installed in the Transmitter, push Remove the wall cover. Remove cover on the wall mounted the On button. The Receiver will “beep” four times to indicate battery back-up holder.
  • Page 5 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Turn On the Appliance With the system OFF, press the ON/OFF Button on the Transmit- ter. The Transmitter display will show some other active Icons on the screen. At the same time the Receiver will activate the appli- ance.
  • Page 6 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS The Thermostat Feature may be disabled if desired. With all three AAA type batteries installed: Take out one AAA battery. While re-inserting the AAA battery, Push and hold down the thermostat button. This will disable the thermostat feature on the transmitter.
  • Page 7 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Remote Dimmer Control (Light) The auxiliary function controls the AUX power outlet by the dim- mable light control. To activate this function, use the Mode Button (Figure 3) to index to the AUX icon. See Figures 20 and 21. The intensity of the output can be adjusted through six levels.
  • Page 8 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Continuous Pilot/Intermittent Pilot (CPI/IPI) Selection Button Lock With the system in “OFF” position press the Mode Button This function will lock the Buttons to avoid unsupervised operation. (Figure 3) to index to the CPI mode icon. See Figures 26 To activate this function, press the MODE and UP Buttons at the and 27.
  • Page 9 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Using the Fireplace without a Remote Control Lockout State Definition The fireplace can be turned ON (HI only) and OFF with the wall A lockout state is reached when an ignition error occurs. The switch. The fireplace flame ON/OFF is the only function that will lockout state will remain set in memory as long as the power operate;...
  • Page 10: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance must be lighted with the remote control. C.
  • Page 11: Maintenance And Service

    Empire Comfort Systems. • Clean Burner and Control Compartment Do not abuse or strike the glass. Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
  • Page 12 2. Remove old light bulb and replace with a new one. (See Figure 33) NOTE: You may order light bulbs from your local Empire dealer or purchase them from your local hardware store. LIGHT BULB SPECIFICATIONS 35w Clear Halogen, Bi-Pin 6.35mm base,120vac, UL...
  • Page 13: Important Safety Information

    IMPORTANT SAFETY INFORMATION For the Homeowner Annual Inspection • This fireplace must be installed and serviced by your dealer • Have the fireplace inspected annually before use. or a qualified service technician. Other than cleaning the • More frequent inspection and cleaning may be required if the glass and replacing the light bulbs, there are no user- fireplace is installed in an area exposed to pet hair or dust, serviceable components.
  • Page 14: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause That will take some of the odorant out of the gas, reducing fires and explosions. In its natural state, propane is its odor intensity. odorless and colorless.
  • Page 15: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 4. INSPECTION. The state or local gas inspector of the installed in every dwelling, building or structure used in side wall horizontally vented gas fueled equipment whole or in part for residential purposes, including those shall not approve the installation unless, upon owned or operated by the Commonwealth and where the inspection, the inspector observes carbon monoxide...
  • Page 16: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods speci- fied below. Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.