2 SPECIFICATIONS

2.1 NovaDrier STANDARD COMPONENT Set Points

Air Amplifier setting:
LOWER air pressure regulator setting (R1) - located inside the
upper part of the control box:
UPPER air pressure regulator setting (R2) - located inside the
lower part of the control box:
Low air pressure switch:
Over-temperature shut-down set point from both the
temperature controllers (see **note above):
Angle needle valve that controls flow to Hygro Dew Point Sensor
option (if supplied):
Heater Thermostats - legend "TSH" (if supplied):
Instruction Manual IM ND 3 JAN 2017
ALL MODELS
Required Compressed
Air Pressure - PSIG
Max. Temperature
°F/ºC
Max Inlet Dew Point
°F/ºC
Process Air Outlet
Temp. °F/ºC (max)
Process Air Dew Point
(max)
**Note: If set point is exceeded by 5°F (3°C) the heater will shut down for 1
minute to allow it to come back to set point. If it does not, the dryer will alarm
and shut down.
Instruction Manual ND IM 3 JAN 2017
85-125 psig (5.9 -8.7 Barg)
100°F / 38°C
100°F / 38°C
350ºF / 163°C
-40ºF / -40ºC
See sticker inside control box
See sticker inside control box
See sticker inside control box
70 PSIG (4.7 BagG)
5°F (3°C) higher than the control set
point after one minute
(2) turns open from full closed
375°F (191°F)
Page 7