BST KLC 20 Technical Information

Wide band flame detector
Hide thumbs Also See for KLC 20:

Advertisement

Quick Links

KLC 20
KLC 20
Technical Information
Technical Information
Wide Band Flame Detector KLC 20
Wide Band Flame Detector KLC 20
for all kind of oil flames with intermittent burner operations
for all kind of oil flames with intermittent burner operations
for all kind of oil flames with intermittent burner operations
Short Description
The wide band flame detector KLC 20 is a compact flame detector, which is special designed for
The wide band flame detector KLC 20 is a compact flame detector, which is special designed for
The wide band flame detector KLC 20 is a compact flame detector, which is special designed for
blue burning combustion systems. The patented evaluation of the flame signal is based on the
blue burning combustion systems.
flicker frequencies of the flame. A RISC-Processor enables the evaluation and conversion of the
flicker frequencies of the flame.
flame signal into digital information to provide an output signal for burner control boxes. All flames
flame signal into digital information to provide an output signal for burner control boxes. All flam
flame signal into digital information to provide an output signal for burner control boxes. All flam
will be detected by an automatic sensitivity control. Adjustments during commissioning and
will be detected by an automatic sensitivity control.
maintenance are not necessary!
maintenance are not necessary!
Due to international standards the flame detector KLC 20 will only detect signals caused by the
Due to international standards the flame detector KLC 20 will only detect signals caused by the
Due to international standards the flame detector KLC 20 will only detect signals caused by the
flicker of the flame and no signal from continuous radiation and all kinds of constant frequency.
flicker of the flame and no signal
These fare signals caused by disturbing light sources, e.g. fluorescent tubes or background
These fare signals caused by disturbing light sources, e.g. fluorescent tubes or background
These fare signals caused by disturbing light sources, e.g. fluorescent tubes or background
radiation from hot refractories will be cut off, so that unwanted influences are not possible.
radiation from hot refractories will be cut off, so that unwanted influences are not possible.
radiation from hot refractories will be cut off, so that unwanted influences are not possible.
The flame detector is equipped with an optical interface to get online information about monitoring
lame detector is equipped with an optical interface to get online information about monitoring
lame detector is equipped with an optical interface to get online information about monitoring
of flame signal and serial number.
of flame signal and serial number.
(formerly known as KLC 2002)
(formerly known as KLC 2002)
The patented evaluation of the flame signal is based on the
Processor enables the evaluation and conversion of the
from continuous radiation and all kinds of constant frequency.
Adjustments during commissioning and
TB_KLC_20_EN_REV1.DOCX
CE0085BP0001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KLC 20 and is the answer not in the manual?

Questions and answers

Summary of Contents for BST KLC 20

  • Page 1 Short Description The wide band flame detector KLC 20 is a compact flame detector, which is special designed for The wide band flame detector KLC 20 is a compact flame detector, which is special designed for The wide band flame detector KLC 20 is a compact flame detector, which is special designed for blue burning combustion systems.
  • Page 2: Safety Instruction

    Safety Instruction The KLC 20 is a safety component, so it is absolutely forbidden to open, to manipulate or to misuse this flame detector! Replace the flame detector in case of any damage, fall, shock, moisture, wetness or influences, which can destroy the flame detector, even though it is not recognizable! Repair works are strictly prohibited! Before working at the flame detector switch off the power supply.
  • Page 3: Block Diagram

    Block diagram Mounting instructions The KLC 20 should be mounted close to the flame with straight alignment. The compact flame detector should be mounted with the mounting flange KLC or another suitable holder with Ø14 mm opening. The radial adjustment to the flame is realised with the viewing angle adapter KLC and replaces the mounting flange KLC.
  • Page 4 Mounting flange KLC The mounting flange KLC serves for to the admission, attachment and adjustment of the flame detector. Two overall heights with 7 and 13mm are available. By means of an O-ring the mounting flange KLC can be simply sealed to the burner housing. Viewing Angel Adapter KLC for radial adjustment With the optionally available viewing angle adapter by means of an optimally formed out reflector surface the radial adjustment of the...
  • Page 5 Dimensions 13,5 Viewing Angel Adapter KLC: all dimensions in mm Connector Diagram KLC 20 Control boxes Dungs / Satronic DKO 9.. Type of control box MPA 22 TF 8.. DKW 9.. TMO 720-4 DMO 9.. 12 – 5 N Blue terminal no.:...
  • Page 6: Commissioning And Maintenance

    In this case the KLC 20 will switch the output a first but after a period of . In this case the KLC 20 will switch the output a first but after a period of .
  • Page 7: Disposal Information

    Overview of articles Article Version Part-No. Flame detector KLC 20/230 Axial, with disturbing 611120110105 frequency cut off Flame detector KLC 20/230 Axial, with disturbing frequency cut off and optical 611120112105 IR – Filter Flame detector KLC 20/230 Axial, without disturbing...
  • Page 8 DIN EN ISO 9001:2000 BST Solutions GmbH Zertifikat: 09 100 5438 Eggerscheidter Straße 57 D - 40883 Ratingen Telefon: +49 (02102) 1005959 Telefax: +49 (02102) 1005979 Email: info@bst-solutions.de http://www.bst-solutions.de © BST Solutions 2015 technical modification reserved Revision 1 - 8 - TB_KLC_20_EN_REV1.DOCX...