AXIS D2050-VE Network Radar Detector
Product overview
each other. Detectors that are mounted one above the other do not cause interference, no matter the distance.
At the recommended mounting height, the near detection limit is 4.5 m (15 ft).
If there are a lot of metal objects in the field of view there will be a lot of reflections impacting the performance.
Note
Do not repaint the detector. The paint may seriously impact the detector's performance.

Mounting direction

The detector covers an angle of ±60° from its central axis. This means that if you mount it on a wall there is a blind spot to each
side of the detector.
To cover the wall you can move the radar module inside the detector.
1
-25° mounting direction
2
0° mounting direction
3
25° mounting direction

Mounting height

For optimal performance, install the detector 3.5 m (11 ft) above ground.