Page 2
Every care has been taken in the preparation of this Class A digital device, pursuant to part 15 of the FCC Rules. document. Please inform your local Axis office of any These limits are designed to provide reasonable protection inaccuracies or omissions. Axis Communications AB cannot...
Page 3
Directiva 2014/53/CE. • report problems to Axis support staff by logging in to your private support area ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Axis Communications AB ΔΗΛΩΝΕΙ •...
Page 4
Learn more! Visit Axis learning center axis.com/academy for useful trainings, webinars, tutorials and guides.
Do not repaint the detector. The paint may seriously impact the detector’s performance. Mounting direction The detector covers an angle of ±60° from its central axis. This means that if you mount it on a wall there is a blind spot to each side of the detector.
Page 8
AXIS D2050-VE Network Radar Detector Note If you install the detector at a different height, enter the actual mounting height in the product’s web pages before calibrating the radar. The following table shows the detection range at different mounting heights when detecting a 1.8 m (6 ft) tall person walking.
AXIS D2050-VE Network Radar Detector How to install the product WARNING Risk of electric shock. The product shall be grounded either through a shielded network cable (STP) or using a grounding wire. If using a grounding wire, make sure both ends of the grounding wire are in contact with their respective grounding surfaces.
Page 10
AXIS D2050-VE Network Radar Detector Hook, bracket side Hook, detector side Screw (2x) 8. Remove the right hand cable gasket and pull the tab to open a hole for the network cable. Ground/Relay Network...
Page 11
AXIS D2050-VE Network Radar Detector NO TICE TICE TICE • If more than one cable is used, each cable must be routed through a separate cable gasket. • Only open a hole in cable gaskets that will be used and if a cable gasket is torn, replace it with a new cable gasket.
Page 12
AXIS D2050-VE Network Radar Detector Gasket Body Seal Plug (discard) 14. If using a grounding wire, attach it to the cable shoe using cable shoe pliers. Attach the cable shoe to the grounding screw. Make sure the cable shoe is in contact with the grounding surface.
OS X ® • Chrome or Firefox with other operating systems. To find out more about how to use the product, see the User Manual available at axis.com If you need more information about recommended browsers, go to axis.com/browser-support...
AXIS D2050-VE Network Radar Detector Configure the detector The detector is ready to use as soon as it is installed. The default live view will show the radar coverage and any detected movement, and you can add detection zones and action rules right away.
AXIS D2050-VE Network Radar Detector • Calibration using pins: The calibration is performed in the web interface by dropping pins in know locations in the reference map and setting the distance between the pins. When calibrating using pins, you need to select the mounting position of the radar module inside the detector.
AXIS D2050-VE Network Radar Detector How to reset to factory default settings Important Reset to factory default should be used with caution. A reset to factory default resets all settings, including the IP address, to the factory default values. To reset the product to the factory default settings: 1.
To check if there is updated firmware available for your product, see axis.com/support • For useful online trainings and webinars, see axis.com/academy Optional accessories For a complete list of available accessories for this product, go to the product’s page on axis.com and select Software & Accessories. • T91A47 pole mount •...
AXIS D2050-VE Network Radar Detector Specifications To find the latest version of the product’s datasheet, go to the product page on axis.com and locate Support & Documentation. LED Indicators Status LED Indication Green Steady green for normal operation. Amber Steady during startup. Flashes when restoring settings.
AXIS D2050-VE Network Radar Detector Connectors Network connector RJ45 Ethernet connector with Power over Ethernet Plus (PoE+). I/O connector Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm notifications. In addition to the 0 V DC reference point and power (DC...
AXIS D2050-VE Network Radar Detector 0 V DC (-) DC output 12 V, max 50 mA I/O configured as input I/O configured as output Relay connector CAUTION Use single core wires for the relay connector. Function Specifications Type Normally open...
AXIS D2050-VE Network Radar Detector Isolation from other circuitry 2.5 kV Electrical endurance 24 V DC, 25 000 operations at +70°C (158 °F) Operating conditions Product Classification Temperature Humidity AXIS D2050-VE IEC 60529 IP66 -40 °C to 60 °C 10–100% RH (condensing) NEMA 250 Type 4X (-40 °F to 140 °F)
AXIS D2050-VE Network Radar Detector Safety information Hazard levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Axis or a third party. Axis recommends using Axis power source equipment compatible with your product. • Use only spare parts provided by or recommended by Axis. • Do not attempt to repair the product yourself. Contact Axis support or your Axis reseller for service matters. Transportation...
Page 25
WARNING • Risk of explosion if the battery is incorrectly replaced. • Replace only with an identical battery or a battery which is recommended by Axis. • Dispose of used batteries according to local regulations or the battery manufacturer's instructions.