The burner does not ignite (when
the dryer is running). The
burner alarm light is on.
The elevator motor protection
relay trips
When the switch is in the filling
position, only the pre-cleaner is
functioning and if the switch is in
the drying position, the furnace
fan and the pre-cleaner are
functioning, otherwise the dryer
does not respond.
The earth leakage circuit
breaker trips
The functioning of the dryer
lights during the drying process
is abnormal or no power is
supplied to the switchboard of
the dryer.
Note!
If you have reset any of the motor protection relays, and the relay trips again immediately after the
next start-up attempt, and this happens during the warranty period, contact the manufacturer's
maintenance workshop and agree on the possible remedy measures. The fault is either in the motor
protection relay or the motor connected to it. Therefore it is advisable that the manufacturer's
maintenance technician or the local authorised electrical workshop comes and finds the cause of the
fault.
36
The burner has run out of
oil
The fuel filter is clogged
The burner settings are off
Defective burner
The elevator is clogged
The elevator belt is loose
The elevator rotation
sensor has tripped
Any of the switched-on
motors is "leaking"
The zero phase in the dryer
feed is missing
Any of the fuses in the
power supply circuit has
blown
The earth leakage circuit
breaker has tripped
The power cable of the
dryer is damaged
Check oil level
Check the condition of oil hoses
Check the hose arrangement
Check/ replace the filter and the gaskets
Reset the malfunction
If the burner does not start or if the
problem reappears, contact the burner
maintenance specialist
Check the elevator. Rotate the elevator by
turning the belt pulley:
- If the elevator feels heavy, it is probably
clogged.
- If the elevator feels light, the chain is
probably loose.
Tighten the chain
Check the elevator. Rotate the elevator by
turning the belt pulley, if the elevator
feels heavy, it is probably clogged, and if
the elevator feels light, the chain is
probably loose.
Tighten the chain
Reset the rotating sensor by switching the
power off and on with the main switch.
Call the electrician.
Check the power cable
Check the zero phase
Check whether the fuses in the power
supply circuit are intact
Check the main switch of the dryer
D00125-2019_EN