Configure Output Modules

For use with the MAOC instruction, output modules require minimal
configuration:
• When using a scheduled output module, the outputs associated with the
MAOC instruction operate independently of the requested packet
interval (RPI). Standard output modules are typically updated at the RPI,
but can be updated faster in certain circumstances.
• To associate an output module with an MAOC instruction, assign the
module's scheduled data tag to the output tag in the instruction. Using any
tag other than the scheduled data tag can cause problems with the
execution.
• For the 1756-OB16IS, 1756-OB16IEFS, and 1732E-OB8M8SR
scheduled output modules, use the default settings shown in the figures
below.
Figure 5 - 1756-OB16IS Communication Format
Rockwell Automation Publication 1756-AT017A-EN-P - January 2013
Position-based Output Control with the MAOC Instruction 9