Terminal assignment and commissioning.................13 Electrical connection ........................13 9.1.1 Setting the user address ........................13 9.1.2 Setting the baud rate ........................13 9.1.3 Terminating resistor ........................13 9.1.4 Bus cover connection ........................14 Display elements (status display)....................15 BUDE_Manual_DeviceNet_EN.doc 2/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
Page 3
Disclaimer of liability The present manual was compiled with utmost care, errors and omissions reserved. For this reason Baumer Huebner GmbH rejects any liability for the information compiled in the present manual. Baumer Huebner GmbH nor the author will accept any liability for direct or indirect damages resulting from the use of the present information.
The braided screen, the shield film and the drain wire of the cable must not touch the housing. Failure to observe these instructions can result in malfunctions, material damage or personal injury. Disposal Dispose of encoder components in accordance with locally applicable legislation. BUDE_Manual_DeviceNet_EN.doc 5/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
* Preset value A certain output value is 0.. set overall resolution -1 assigned to the current position value * In the case of singleturn encoders, the measurement range = the resolution BUDE_Manual_DeviceNet_EN.doc 6/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
Position value Position value Position value MSB Warning Alarm flag Reserved flag Examples: Path for instance 1 (in hex): "20 04 24 01" Path for instance 2 (in hex): "20 04 24 02" BUDE_Manual_DeviceNet_EN.doc 8/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
Resets all parameters to the default values. Restore Reloads all parameters from the non-volatile memory. Save Saves all parameters in the non-volatile memory so that they are applicable again after power off/on. BUDE_Manual_DeviceNet_EN.doc 9/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
If the number of turns is programmed as a value not equal to 2 (1, 2, 4,...65536), parameterizing will have to be done anew as soon as the encoder's zero point has been exceeded in powerless state. BUDE_Manual_DeviceNet_EN.doc 10/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
Page 11
High-Word: Software version Read Offset value DINT The offset value is calculated within the preset function and shifts the position value by the calculated value Read Encoder type UINT Describes the encoder type BUDE_Manual_DeviceNet_EN.doc 11/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
Page 12
Resets all parameters to the default values Restore Reloads the parameters from the non-volatile memory Save Saves all parameters in the non-volatile memory, so that they are valid again after power off/on BUDE_Manual_DeviceNet_EN.doc 12/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
The resistor is in the bus cover and is connected using a DIP switch. The terminating resistor must be switched to "ON" at the last user with a DIP switch (default setting OFF). ON = Final user OFF = User X BUDE_Manual_DeviceNet_EN.doc 13/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...
Tighten both the fastening screws firmly in the same direction. The encoder housing and bus cover are only ideally connected if the bus cover is resting fully on the basic encoder (positive locking). BUDE_Manual_DeviceNet_EN.doc 14/15 Baumer Hübner GmbH 22.10.2010/bja Berlin, Germany...