Environmental Specifications

Operating Temperature
Storage Temperature
Altitude
Non-operating:
Operating:
Operating Relative
Humidity
Influence of Temperature
Influence of Humidity

Safety Specifications

Electrical
Electromagnetic
Compatibility
14 °F to 131 °F (−10 °C to +55 °C)
−40 °F to 158 °F (−40 °C to +70 °C)
0 to 12,000 m
0 to 2000 m
10 °C to 35 °C 85 % RH (without roll-off
above 35 °C)
≤ 150 ppm/ °K, or 0.15 % of mV output per
10 °K
≤ 10 to 90 % RH: 0.2% of mV output per
10 °K @ 18 °C to 28 °C
Conforms to EN/IEC 61010 and 61010-2-
032
600 V Cat. III, Pollution Degree 2
EN 50081-1 Class B
EN 50082-2 Electrostatic discharge;
IEC 61000-4-2
Radiated field IEC 61000-4-3
Fast transients IEC 61000-4-4
Magnetic field at 50/60 Hz IEC 61000-4-8