Huawei ME909u-521 Hardware Manual page 66

Lte lga module
Hide thumbs Also See for ME909u-521:
Table of Contents

Advertisement

HUAWEI ME909u-521 LTE LGA Module
Hardware Guide
Item
Low-temperature
operating
High-temperature
operating
Temperature
cycle operating
Damp heat
cycling
Thermal shock
Salty fog test
Issue 05 (2017-12-15)
Test Condition
Temperature: –30º C
Operation mode: working
with service connected
Test duration: 24 h
Temperature: 75º C
Operation mode: working
with service connected
Test duration: 24 h
High temperature: 75º C
Low temperature: -30º C
Operation mode: working
with service connected
Test duration: 30 cycles;1
h+1 h/cycle
High temperature: 55º C
Low temperature: 25º C
Humidity: 95%±3%
Operation mode: working
with service connected
Test duration: 6 cycles;
12 h+12 h/cycle
Low temperature: –40º
High temperature: 85º C
Temperature change
interval: < 20s
Operation mode: no
power
Test duration: 100 cycles;
15 min+15 min/cycle
Temperature: 35° C
Density of the NaCl
solution: 5%±1%
Operation mode: no
power, no package
Test duration:
Spraying interval: 8 h
Exposing period after
removing the salty fog
environment: 16 h
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Electrical and Reliability Features
Standard
Sample
size
IEC6006
3 pcs/group
8-2-1
JESD22-
3 pcs/group
A108-C
JESD22-
3pcs/group
A105-B
JESD22-
3 pcs/group
A101-B
JESD22-
3 pcs/group
A106-B
JESD22-
3 pcs/group
A107-B
Results
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
66