Troubleshooting
Corrective Actions
CoNDITIoN
Airspeed Awareness
Color Band removed
and SPD message
displayed
Blank display
"BATT WORN OUT...
REPLACE" message
is displayed on screen
during startup
Battery Failed Indicator
4-2
(continued)
CAUSE/CoRRECTIVE ACTIoN
Indicates loss of airspeed configuration
data.
Cycle power to the ESI-2000.
If airspeed configuration data is not re-
stored, ESI-2000 may be defective. Have
ESI-2000 checked by certified service
center.
Brightness level may be low. Press and
hold the Menu M button for at least 5 sec-
onds. Brightness of display should be ob-
served.
ESI-2000 may be defective. Have ESI-
2000 checked by certified service center.
Message will be displayed at startup and
remain on screen for 90 seconds.
The battery can no longer hold a state of
charge greater than 1 hour and requires
replacement.
Have ESI-2000 checked by certified ser-
vice center.
Cycle power to the ESI-2000.
If the red battery failed indicator continues
to be observed after power cycle, battery
system has failed and requires replace-
ment.
Have ESI-2000 checked by certified ser-
vice center.