Installation
4.2.1 Installation of lower and upper
ventilation grilles LS 330.
LS330
H
LS330
The ventilation grilles must have an open
cross-section of at least 400 cm². This is
achieved by using the Dometic LS 330 absor-
ber ventilation and air extraction system which
has been tested and approved for this purpose.
Correct mounting of the lower ventilation grille
facilitates access to the connections and
functional parts during maintenance.
4.3

Installing the ventilation system

4.3.1 Installing LS 330
To install the ventilation grilles, cut two rectan-
gles width a = 249 mm x b = 410 mm, in the
outer wall of the vehicle (for position of the cuts,
see Fig. 11).
1
Cut two rectangles in the
exterior wall of the vehi-
cle.
2
Seal the mounting frame
making it waterproof
( does not apply for
mounting frames with
integral seal) and screw
into position.
3
Insert ventilation grille.
Fig. 11
4
Install locking slider.
5
Lock ventilation grille.
12
b
a
Fig. 12
12 x
Fig. 13
Fig. 14
Fig. 15