Vacuum Pump - Soleus Air 3119233 Owner's Manual

13 seer mini split air conditioner with heat pump and back up electric heat strip
Table of Contents

Advertisement

1 1
Installation Instructions
Outdoor Unit Installation
1.Install Drain Port and Drain Hose (for heat-pump model only)
The condensate drains from the outdoor unit when the unit operates
in heating mode. In order to protect the environment, install a drain
port and a drain hose to direct the condensate water. Just install the
drain port and rubber washer to the chassis of the outdoor unit, then
connect a drain hose to the port as the right figure shown.
2. Install and Fix Outdoor Unit
Fix with bolts and nuts tightly on a flat and strong floor.
If installed on the wall or roof, make sure to fix the supporter well to prevent it
from shaking due to serious vibration or strong wind.
3. Outdoor Unit Piping Connection
Remove the valve caps from the 2-way and 3-way valve.
Connect the pipes to the 2-way and 3-way valves separately according to the required torque.
4. Outdoor Unit Cable Connection (see previous page)
Air Purging
The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the
compressor. After connecting the indoor and outdoor units, evacuate air and moisture from refrigerant
cycle using a vacuum pump, as shown below.
Indoor unit
Refrigerant flow direction
3-way valve
(7) Turn to fully open the
valve
Service
port
(2) Turn
Valve cap
(8) Tighten
Note: To protect the environment, be sure not to discharge the refrigerant to the air directly.
17
2-way valve
(6) Open 1/4 turn
(7) Turn to fully open the valve
valve cap
(1) Turn
(1) Turn
(8) Tighten
Drain port
Drain hose
(prepare by user)

Vacuum pump

3-way valve diagram
(8) Tighten
Connect to outdoor unit
Valve core
Washer
connect to indoor unit
open position
spindle
needle
service port cap