ENROLLING
For Lyric Controller
1. Set the Controller in Programming Mode and select
Zone Programming.
For Lyric: Program > Zones > Add New > Series
Number
2. On the SiXC2W, power up:
• LED #1 flashes for approximately 20 seconds
• LED #1 turns on
• LED #1 turns on for 3-seconds
• SiXC2W sends the information to the control and
the serial number displays for loop 1
3. Edit the zone and response types for the zone and
press Save.
4. To enroll additional zones, activate each loop (one
per zone) when prompted for the serial number.
Zone
Zone 1
Zone 2
Zone 3
Zone 4
Example:
Zones 1-8 can be used for other SiX series devices.
However, zones on the SiXC2W must align with the
assigned loops on the control.
5. The controller registers the device and displays the
sensor data on screen.
MAC #
Loop #
00D02D123456
1
00D02D123456
2
00D02D123456
3
00D02D123456
4
NOTES:
Each SiXC2W has a unique mac number which enables
the control panel to recognize and differentiate each
zone. Further, since the SiXC2W has eight zones each
zone is automatically assigned the next sequential mac
number; all zones are assigned loop 1-8 respectively.
FOR LYRIC GATEWAY
Use AlarmNet 360™ to enroll and program this sensor.
FOR OTHER CONTROLS
For other controls that support SiX series devices, see
the controller's installation app for details
NOTE: Once enrolled in a system, the SiXC2W cannot be
used with another controller until it is removed
from the current controller. See the Controller's
instructions for details
Zone
MAC #
Zone 5
00D02D123456
Zone 6
00D02D123456
Zone 7
00D02D123456
Zone 8
00D02D123456
NOTE: Enrollment time varies depending on the signal
strength between the device and the controller.
When done, LED #1 is ON for 3 seconds and the
control beeps to confirm enrollment.
2
.
Loop #
5
6
7
8