FAULT FINDING

System Status Messages

Status
Message
11
Encoder/Line
too fast
(overflow).
12
Encoder/Line
too slow
(underflow.)
13
List buffer
repeat count
fail.
14
Maximum print
to print
distance
exceeded.
15
Print start
signal ignored.
16
Maximum laser
on time exceed
(laser disabled
by hardware).
17
Laser warm up. A short warm up
30
Scanhead
power missing.
56
Cause
The message has
not been completed
in time.
The message has
not been completed
in time.
Internal Fault.
The maximum
distance between
print go signals has
been exceeded and
an expected print go
was not received.
A print go has been
received too soon
after the previous.
The laser has been
firing for longer than
expected.
period is required
before use.
There is no +/-15v at
the scanhead, or no
data returning from
scanhead.
Suggested Action
Slow down the conveyor,
reduce the mark time, or
move the text upstream on
the field.
Reduce the mark time or
move the text upstream on
the field.
Restart the system. Contact
Domino.
Restart the system. Contact
Domino.
Restart the system. Contact
Domino.
Restart the system. Contact
Domino.
Restart the system. Contact
Domino.
Restart the system. Contact
Domino.