Monitoring And Inspection; Fire Prevention - Yanmar B95W Operating Instructions Manual

Mobile excavator
Table of Contents

Advertisement

3.23
3.24
03_Sicherheit_en.fm - V 0.1 - 1.8.17

Monitoring and inspection

Have the machine inspected by an expert (e.g., mechanical engineer or
machine foreman) according to the regulations in force in the user's country
(e.g., Accident Prevention Regulations in Germany):
• Before the machine is put into operation for the first time and after
significant modifications have been made
• At least once a year
• At between times, according to operating conditions and local environments
Keep a record of the inspection report and file it until the next inspection.
Before the beginning of the shift, check the machine according to the
inspection plan.
Replace hydraulic hoses as soon as the following damage is noticed:
• Damage to the outer layer which reaches the intermediate layer.
• Embrittled patches on the outer layer.
• Deformations when under pressure or without pressure which differ from
the original shape of the installed hose.
• Leaks.
• Damage to the hose fixtures or connectors between the fixtures and hose.
Do not search for leaks on the hydraulic lines merely using your hands – use
cardboard or wood to locate them.
In the event of any liquids that are spat out getting under the skin, a doctor
who is experienced with this kind of injury must be consulted within a matter
of hours.
Always wait until the engine has cooled before checking the coolant level.
Carefully turn the cover to relieve overpressure.
Check the function of the safety devices before using the machine.
In the event of any faults, inform the supervisor immediately; at change of
shifts, also inform the new operator.
In the event of faults that could endanger the operating safety of the machine,
stop operation until the fault is corrected.

Fire prevention

Shut down the engine before refueling and take special care when the engine
is hot.
Never smoke or allow naked flames while refueling the tank of the machine.
Keep the fire extinguisher near the operator's stand.
Its location must be identified by the fire extinguisher symbol.