Download Print this page
Osram Outdoor Fitting Instructions
Osram Outdoor Fitting Instructions

Osram Outdoor Fitting Instructions

Light and motion sensor

Advertisement

Quick Links

OUTDOOR
Light and motion sensor
Fitting instructions
XII 2009
OUTDOOR_ma0912en_we1.02.indd
OSRAM GmbH
Kunden Service Center
Customer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg
Germany
Tel : +49 (0) 1803 677 - 200
(kostenpflichtig / charges apply)
Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de
40083219570616
4008321957061
Description
A
B
Installation
E
F
H
G
60 mm
Purpose and application
The OUTDOOR sensor detects the presence of persons and
measures the intensity of ambient light.
It is ideally suited for indoor and outdoor light applications that
require a high level of protection against outdoor weather condi-
tions (wetness, dirt).
The sensor is designed for wall and ceiling installation.
Function
The sensor works fully automatically and is used for contact-
free switching. The values detected by the sensor (motion,
light value) control the switching behaviour on the basis of the
settings created by the user.
The following settings can be made:
Delay (if no motion is detected)
Light switching threshold
Operating mode
Design
The sensor is made up of the following components:
Light and motion sensor with an integrated LED (A)
Buttons S1 and S2 (B)
Swivel arm (C)
Connection box (D)
C
D

Safety instructions

The sensor must only be installed and put into operation by a
qualified electrician. The applicable safety regulations and ac-
cident prevention regulations must be observed.
WARNING!
Exposed, live cables.
Danger of electric shock!
CAUTION!
Destruction of the sensor and other devices through
incorrect mounting!
Installation notes
The sensor can be mounted on a flush-mounted box with a
60 mm diameter.
Install the connection box with the correct orientation so that
the sensor has the correct position when it is connected.
Maintain a minimum distance of 0.5 m to luminaires or heat
sources (e.g. heater) to avoid undesired switching of the mo-
tion sensor due to light or false motion from heat.

Installation procedure


Route the connection lines through the knockouts (E) of the
connection box.
Knock out the condensation water opening (H) if necessary.
F
ƒ
Attach the connection box to the wall or ceiling (G) using the
accessories included. Note the installation length.
Connect the connecting lines to the terminals (F); see „Con-
nection diagram".
Attach the swivel arm with the sensor to the connection box
and fix it with the screw integrated in the joint. This ensures
compliance with protection type IP 55.
Switch on the power supply.
The sensor is initialised (during initial startup, it also goes into
test mode) and is then switched to normal mode with the default
settings; see the operating instructions.
Only work on the sensor when it is de-energised.
Protect the supply line with a circuit breaker or
fuse (max. 10 A).
Adhere to the connection diagram.
Page 1 of 3

Advertisement

loading
Need help?

Need help?

Do you have a question about the Outdoor and is the answer not in the manual?

Questions and answers

Summary of Contents for Osram Outdoor

  • Page 1: Safety Instructions

    The OUTDOOR sensor detects the presence of persons and measures the intensity of ambient light. OUTDOOR It is ideally suited for indoor and outdoor light applications that require a high level of protection against outdoor weather condi- tions (wetness, dirt).
  • Page 2 Connection diagram Installation (cont.) J Individual circuit K Load (ECG, lamps, etc.) L Connection box 10 A L L’ M Individual circuit with optional pushbutton/switch N Pushbutton/switch 10 A L L’ Adjusting the detection area Motion detection can be checked in test mode; see the operat- ing instructions.
  • Page 3 Verical detection area Installation (cont.) R Turn the swivel arm to adjust the orientation (max. 120°). Appendix Technical data Operating voltage 230 V AC/50-60 Hz Switch output load capacity Incandescent lamp: 2300 W HV halogen lamps: 1500 W Fluorescent lamps: 1000 VA Inductive load: 600 VA Max.