Technical data

Linearity range: -0,4 to +4,25 mm (-0.0157 to 0.1673") in the diameter, do
not operate the precision adjustable head outside of the adjustment range
Linearity error m w5 µm in the diameter
Max. coolant pressure: 50 bar
Head diameter: 65 mm
Height: 71 mm
Weight of head without tool: 1.65 kg
Max. speed: 20,000 rpm in central position (see page 26)
Balance: Part balancing
Working temperature: + 10 °C to + 40 °C (+50° F to + 104° F)
Storage temperature: - 20 °C to + 60 °C (-4° F to + 140° F)
Connection point: ABS 50
Protection class: IP67
Lithium-ion battery: 2/3 AA SL 761
Commercially available hex key WAF 3/WAF 4

Product cleaning

- Do not use any solvent-based cleaning agent to clean components.
- Clean the display before use.
- After use, coat the precision adjustment head with a thin film of oil.