Download Print this page

Komet 555 Instructions For Use

Milling base

Advertisement

Quick Links

Manufacturer:
Gebr. Brasseler GmbH & Co. KG
Trophagener Weg 25
32657 Lemgo · Germany
Milling base
© 08/2012, Gebr. Brasseler GmbH & Co. KG
306223 - Rev 08/2012
ö ê í
¿
Order number
Numéro d'ordre
Número de pedido














Start-up and appropriate use · Mise en service et utilisation appropriée · Puesta en marcha y uso apropiado
Fig. 1
ö
Milling base
1. Product description
This milling base for the dental laboratory consists of two main components and is provided with a chucking
device allowing work on cylindrical and slightly tapered laboratory replica, either manually or with the milling
device. After removal of the upper part to carry out free-handed work, this can be placed back into its original
position which is fixed by the lower part of the milling base.
2. Functional overview – milling base 555
- Suitable for cylindrical and slightly tapered laboratory replica/implants with diameters ranging from
1 to 6.5 mm
- Internal height adjuster for individually adjusting the position of the replica
- The milling base can be fixed to a magnetic or model table
- Two-piece construction to allow flexible work (milling device or free-handed)
- Quick removal and repositioning of the chuck, thanks to screw-on locking bolt
- Ergonomically shaped clamping nut
- No risk of injury caused by fast generation of heat
- Metal parts made of stainless steel
3. Start-up and appropriate use
Milling device
- Unscrew clamping nut. Choose the clamping jaw according to the diameter of the laboratory replica or implant
and place into the chuck (fig.1). Screw clamping nut back on until slight resistance can be felt.
- Insert laboratory replica/implant into the clamping jaw and clamp gently by fastening the clamping nut.
- Thanks to a through-hole at the underside of the base, the height adjuster can be set to the required height
with a slotted screw driver to suit the laboratory replica/implant to be worked on (fig. 2). Then fix the laboratory
replica/implant in its final position with the clamping nut.
- Fix the chucking device to the base plate with the locking bolt.
- Use on a magnetic or model table.
Free-handed use
- Loosen locking bolt with 0.5 – 1 turns, pull black handle, twist by 90° and deposit on the rests provided to
prevent the spring from snapping back (fig. 3).
- Remove chucking unit (fig. 4) and use for free-handed work.
Repositioning the chucking unit
- Place chucking unit into the base plate.
- Turn the handle of the locking bolt by 90° towards the grooves (does not yet lock at this stage)
- Turn chucking unit in the base plate until the handle of the locking bolt catches
- Fasten the chucking unit with the locking bolt
Distributor/Importer for USA and Canada:
Komet USA LLC
3042 Southcross Blvd, Suite 101
Rock Hill, SC 29730, USA
Phone: 888-566-3887
Fax:
800-223-7485
info@kometusa.com
www.kometusa.com
CAUTION: U.S. Federal law restricts the device
to sale by or on the order of a licensed dentist.
|
LOT number
Numéro de lot
Número de lote
Individual components · Composants individuels · Componentes individuales
Milling base
Socle de fraisage
Zócalo de sujeción
para fresado
555
Base plate
Plateau de base
Base
Clamping jaws · Pinces de serrage · Pinzas portapieza
Ø 1 - 2,5 mm
551
Fig. 2
Instructions for use
Please read carefully and retain for future reference.
Conseils d'utilisation
A respecter scrupuleusement et garder cette copie
pour une utilisation ultérieure.
Instrucciones de empleo
Leer detenidamente y guardar este ejemplar para
uso más tarde.
?
Consult instructions for use
Se reporter aux instructions
Observe indicaciones
Chuck
Clamping nut
Mandrin de serrage
Manchon de serrage
Mandril de sujeción
Tuerca de apriete
Ø 2,5 - 4,5 mm
Ø 4,5 - 6,5 mm
552
553


Fig. 3




4. Maintenance



- The individual elements should be cleaned separately in regular intervals.

- To this end, disassemble the milling base and remove any contamination, such as chips and/or residues of
cooling agents and lubricants



- Thoroughly clean the bearing surface of the depression in the base plate and the chuck. Apply a care product



containing oil (e.g. Ballistol)


- Clean the clamping jaws and the reception cone in the collet with extra care to avoid damage to the chucking


mechanism.


- Whenever cooling spray is used, clean the milling base straight after use and apply a care product containing


oil to avoid corrosion.
5. Disassembly/assembly
- Initial situation: complete, with mounted clamping jaw
- Unscrew clamping nut
- Remove clamping jaw
- Unscrew locking bolt
- Remove chuck
- Unscrew height adjuster
To reassemble the milling block, proceed in reverse order
6. Disclaimer of Warranties
ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY
DISCLAIMED. ALL INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST
PROFITS, INJURY TO OTHER PROPERTY, LOSS OF USE OR OTHER COMMERCIAL LOSSES, ARE EXPRESSLY
DISCLAIMED. If, not withstanding the foregoing, consequential and incidental damages cannot be excluded
due to operation of law, such damages are expressly limited in amount to the purchase price of any defective
products.
Store out of children's reach.
For dental use only.
The product has been developed solely for use in dentistry. The user is responsible for testing the material for its
suitability and use for any purpose not explicitly stated in the in struc tions. Descriptions and data constitute no
warranty of attributes and are not binding.
Packing unit
/
Unité d'emballage
Unidad de embalaje
Height adjuster
Butée de réglage
Tope de altura
Fig. 4
Locking bolt
Verrou de blocage
Perno de retención
554

Advertisement

loading

Summary of Contents for Komet 555

  • Page 1    2. Functional overview – milling base 555 - Whenever cooling spray is used, clean the milling base straight after use and apply a care product containing   - Suitable for cylindrical and slightly tapered laboratory replica/implants with diameters ranging from ...
  • Page 2 - Veiller à nettoyer minutieusement les pinces de serrage et le cône de réception du mandrin pour éviter toute détérioration de l’unité de serrage. 2. Aperçu des fonctions du socle de fraisage 555 - Dans le cas d’une utilisation avec du spray, nettoyer le socle de fraisage immédiatement après l’utilisation et - Approprié...