Section 3: Principals of Operation
October 2017
3�3

Recommended tubing sizes /

Empfohlene Rohrabmessungen /

Aanbevolen buisafmetingen

Actuator Model no�
Antriebstyp
Aandrijving modelnr�
D-12, 25, 40, 65
D-100, 150, 200, 350, 600, 950
D1600
3�4
Air consumption at atmospheric pressure /
Luftverbrauch bei Atmosphärendruck /
Luchtverbruik bij atmosferische druk
D12
Air chamber
A
0.05
B
0.06
Air chamber
A
3.1
B
3.7
-
Model
-
Air chamber
6 6
Runs up to 1�2 mtr / 4ft
6 mm / 1/4"
6 mm / 1/4"
6 mm / 1/4"
Actuator type / Modell / Model
D25
D40
D65
litre/stroke - (Ltr./Hub) - liter/slag
0.10
0.16
0.22
0.11
0.22
0.36
6.1
9.8
13
6.7
13.4
22
-
-
Installation, Operation and Maintenance Manual
Bis 1,20 m
Tot 1,2 m
D100
D150
D200
0.35
0.84
0.8
0.49
0.78
1.0
cu.in./stroke
21
51
49
30
48
61
Modell
Luftkammer
DOC.BD.EDN Rev. 0
Runs over 1�2 mtr� / 4ft
über 1,20 m
meer dan 1,2 m
6 mm / 1/4"
8 mm / 5/16"
10 mm / 3/8"
D350
D600
D950
1.2
2.9
4.7
1.8
3.1
4.9
73
177
287
110
189
299
-
Model
-
Luchtkamer
Principals of Operation
D1600
7.3
8.0
445
488