New M-Bus
Baudrate
M-Bus Address
Connect
to meter
Manufact.
Generation
Type
M-Bus State
ZVEI optical
mode
Autom. readout
PadPuls M1 User Manual
GmbH, Stettiner Str. 38, D-33106 Paderborn
identical to the baudrate of the M-Bus device. (see: "New M-Bus
Baudrate"). The PadPuls M1 supports the baudrates 300, 2400 and
9600Bd.
allows reprogramming the baudrate of the M-Bus device. The new
baudrate is sent to the M-Bus device after a change in the
appropriate selection box. If the M-Bus slave accepts this
command, it acknowledges the telegram with the single character
„$E5" ($ for hexadecimal notation) using the old baudrate.
Afterwards the device switches to the new baudrate. This button is
not needed for the PadPuls M1, since it automatically detects the
baudrate used by the master.
is the primary address of the connected M-Bus slave. In a direct
connection with only one slave you can use the broadcast address
254. Using this address every M-Bus device must answer
regardless of its own address.
is used to request data from the slave. The type of device is then
automatically recognized. The items "Manufact.", "Generation",
-Bus State" will then be refreshed. New sheets are
generated depending on manufacturer and type of the M-Bus
device. In case of PadPuls M1 a sheet labelled with "PadPuls M1"
appears.
is an item that shows the 3-letter manufacturer code after
successful reading ("Connect to meter"). The item is read only.
shows the software revision of the firmware of the connected M-
Bus device. The item is read only.
shows the type (here: PadPuls M1) of the connected device. This
item is read only.
shows the M-Bus state of the connected device. This item is read
only.
If this option is activated, devices with an optical interface and
protocol according to EN 1434-3 can be read and programmed
using an optical reading head (e.g. PadPuls M4 / M4L).
The software always reads the data after writing, if this option is
activated (useful for checking the correct programming).
26.09.01, Version 1.3