Article no. IM001:
Article no. IM001G:
Contents
1 Functional description .................................................................................................. 2
2 Installation and startup ................................................................................................. 3
2.1 Mounting the case ................................................................................................. 3
2.2 Opening the case .................................................................................................. 3
2.3 Connecting ............................................................................................................ 3
3 Parameterization using MBCONF................................................................................ 5
3.1 Installation ............................................................................................................. 5
3.2 Operation............................................................................................................... 5
3.3 Sheet Info .............................................................................................................. 6
3.3 Sheet PadPuls M1................................................................................................. 9
4 M-Bus Telegrams....................................................................................................... 12
5 Technical data............................................................................................................ 14
PadPuls M1 User Manual
GmbH, Stettiner Str. 38, D-33106 Paderborn
PadPuls M1
Art. no.: IM001 + IM001G
(Valid from M-Bus generation: $07)
1-channel pulse collector (OEM board)
1-channel pulse collector with case for wall-mounting
26.09.01, Version 1.3
1

Advertisement

Table of Contents
loading

Summary of Contents for Relay PadPuls M1

  • Page 1: Table Of Contents

    2.3 Connecting ......................3 3 Parameterization using MBCONF................5 3.1 Installation ......................5 3.2 Operation....................... 5 3.3 Sheet Info ......................6 3.3 Sheet PadPuls M1....................9 4 M-Bus Telegrams....................... 12 5 Technical data......................14 PadPuls M1 User Manual 26.09.01, Version 1.3...
  • Page 2: Functional Description

    However, the meters to be adapted must have a floating pulse output. The user can configure the PadPuls M1 with the MBCOPNF program so that the scanned impulses are converted to units such as kWh, m , J and so on.
  • Page 3: Installation And Startup

    Use a suitable adhesive seal to prevent the housing from being opened unnoticed. 2.3 Connecting The following picture shows a typical installation including the PadPuls M1: Pulse-generator PadPuls M1...
  • Page 4 The following graphic shows the position of the terminals and the button: jumper battery lithium battery 3,0V / 1800 mAh terminal terminal M-BUS pulse unprotect 26.09.01, Version 1.3 PadPuls M1 User Manual...
  • Page 5: Parameterization Using Mbconf

    Windows 95 / 98 / NT 4.0. The desktop PC or laptop must have a free serial RS232C interface to connect the M-Bus level converter. The PadPuls M1 to be parameterized must be connected directly (i.e. as only M-Bus device) to the M-Bus output of the level converter.
  • Page 6: Sheet Info

    This sheet shows some photos of supported M-Bus devices from the product range of the Relay GmbH, the PadMess GmbH and further manufacturer. Here are also links to the Internet page, from which the current version of the program can be downloaded, and to the email address for criticism and suggestions to the program.
  • Page 7 The items “Manufact.”, “Generation”, -Bus State” will then be refreshed. New sheets are generated depending on manufacturer and type of the M-Bus device. In case of PadPuls M1 a sheet labelled with “PadPuls M1” appears. Manufact. is an item that shows the 3-letter manufacturer code after successful reading (“Connect to meter”).
  • Page 8 The following buttons are also always visible: Erase log clears all outputs inside the log window. Exit terminates the program and stores the current setting of serial port (port no.) into the INI file. 26.09.01, Version 1.3 PadPuls M1 User Manual...
  • Page 9: Sheet Padpuls M1

    GmbH, Stettiner Str. 38, D-33106 Paderborn 3.3 Sheet PadPuls M1 These sheet shows the actual settings and values of the PadPuls M1. The following input boxes and buttons are used to change the params of the pulse adapter: Primary address is the M-Bus address of the device.
  • Page 10 “Unprotect” pushbutton. Permanent error is insignificant for the PadPuls M1. Write protect Transmits a command to the PadPuls M1 to activate write protection. The PadPuls then allows no further configuration. It is protected against unnoticed manipulation. Read reads the M-Bus device and refreshes the data on the selected sheet.
  • Page 11 Choice: Unit = 1kWh, Multiplicator = 1 / 64, Counter = 78346 ( x 1kWh) • Electricity meter with counter = 112,345 kWh and 1000 pulses / kWh: Choice: Unit = 1Wh, Multiplicator = 1 / 1, Counter = 1123454 ( x 0,001Wh) PadPuls M1 User Manual 26.09.01, Version 1.3...
  • Page 12: Bus Telegrams

    • VIF: Set by the user; VIF = unit with decimal power (MSB not set) • Count: Meter reading (most-significant byte = Count6 always zero) • Numerator / Denominator: Impulse value (increment in multiples of the VIF per impulse): Numerator • VIF 1 Pulse = Denominator 26.09.01, Version 1.3 PadPuls M1 User Manual...
  • Page 13 4) Telegram to Set the Write Protection Byte Name Start Length Length Start Spez. Protect Stop Inhalt The write protection can only be reset by pressing the pushbutton on the circuit board. PadPuls M1 User Manual 26.09.01, Version 1.3...
  • Page 14: Technical Data

    Current consumption Principle Remote power supply from M-Bus with automatic changeover to battery backup upon bus failure Battery Lithium 3V, model 2/3AA, 1700mAh Bus operation max. 1.5mA (1 unit load), no battery loading 26.09.01, Version 1.3 PadPuls M1 User Manual...
  • Page 15 M-Bus: physical characteristics M-Bus quiescent current typ. 1.25 mA, max. 1.5mA (1 unit load) Space (0-bit) current quiescent current + typ. 13 mA M-Bus interface TI TSS721 with 2 x 215Ω protection resistors PadPuls M1 User Manual 26.09.01, Version 1.3...
  • Page 16 GmbH, Stettiner Str. 38, D-33106 Paderborn Notizen: 26.09.01, Version 1.3 PadPuls M1 User Manual...