Triplex ceramic plunger pump
Table of Contents

Advertisement

Exploded View - LP121A-5100, LP200-5100, and LP250-5100
Important! The stainless steel valve plugs (48) can seize when being screwed out of the casing.
To release tension beforehand, strike the plugs 1-2 times with a steel hammer on the top before
screwing them out. Coat threads with antiseize (e.g. Fel-Pro Nickel Anti-Seize 51119)