10%. resistance of the pump material. It is the re- sponsibility of the equipment manufacturer and/or operator to ensure that all pertinent safety regulations are adhered to. NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600...
LP121A, LP121A-0011, LP200, LP250, and LP250W-MT - Repair Instructions 2. Remove the compression 3. Remove the complete 1. With a 30mm wrench, spring (45), O-rings and valve assembly (46A-46D) remove the 3 plugs (48). support rings (44A & 44B). with valve pullers.
Page 8
LP121A, LP121A-0011, LP200, LP250, and LP250W-MT - Repair Instructions 38/38A 8. Remove seal case (37) from valve casing (43) 9. Check plunger surface (29B). If plunger pipe is worn, loos- en tension screws (29C) and pull off plunger pipe to the and inspect O-rings (38/38A).
LP121A, LP121A-0011, LP200, LP250, and LP250W-MT - Repair Instructions To Dismantle Gear End After removing valve casing (43) and plunger pipe (29B), drain oil. Remove crankcase cover (4) and bearing cover (14). Loosen connecting rod screws (24A) and push the front of the connecting rod (24) forward as far as possible into the crosshead guide.
Replace plungers Inlet pressure too high Reduce inlet pressure High Crankcase Wrong Grade of oil Giant oil is recommended Temperature Improper amount of oil in crankcase Adjust oil level to proper amount Preventative Maintenance Check List & Recommended Spare Parts List...
LP121A, LP121A-0011, LP200, LP250 & LP250W-MT Dimensions - mm (in)
Page 12
NON-SALINE, clean water applications. One (1) year from the date of shipment for all other Giant industrial and consumer pumps. Six (6) months from the date of shipment for all rebuilt pumps.