3.2.6 E593
Code
E593
Detail
Error
Description
8001
Horizontal
registration
motor(M62)/
Horizontal
registration home
8002
position sensor
(PI61)
T-3-8
Detection timing
At time of horizontal registration motor
initialization, the punch slide unit does not
leave the horizontal home position sensor
even when it has been driven for 9 mm.
At time of horizontal registration motor
initialization, the punch slide unit does not
return to the horizontal registration home
position sensor even when the unit has been
driven for 37 mm.
Chapter 3
0003-4742
3-7