SICK RMS3 Series Operating Instructions Manual
SICK RMS3 Series Operating Instructions Manual

SICK RMS3 Series Operating Instructions Manual

Radar sensors
Hide thumbs Also See for RMS3 Series:

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
RMS3xx
Radar sensors

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMS3 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK RMS3 Series

  • Page 1 O P E R A T I N G I N S T R U C T I O N S RMS3xx Radar sensors...
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modifica‐...
  • Page 3: Table Of Contents

    General faults, warnings, and errors............Repairs...................... Returns...................... Disposal..................... Technical data..................25 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 4 12.1 EU declaration of conformity / Certificates..........12.2 Licenses....................O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 5: About This Document

    … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx...
  • Page 6: Safety Information

    When reselling the device, inform the buyer about the regional approval restric‐ tions. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 7: Limitation Of Liability

    Modifications and conversions to the device may result in unforeseeable dangers. Interrupting or modifying the device or SICK software will invalidate any warranty claims against SICK AG. This applies in particular to opening the housing, even as part of mounting and electrical installation.
  • Page 8: Operational Safety And Particular Hazards

    Safety requirements relating to work on electrical systems must be complied with. ■ O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 9 Install the grounding for the sensor and the system in accordance with national ■ and regional regulations. 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 10: Product Description

    Status indicators Figure 1: Status indicators Power Link O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 11 Ö / yellow tion Ö = illuminated; Ö = flashing 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 12: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all ■ components and packaging on a regular basis. O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 13: Mounting

    Use of a weather hood and a mounting bracket is recommended for outdoor instal‐ lations. Information about optional accessories, "Accessories", page 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 14: Electrical Installation

    (same ground potential at all grounding points), take measures in accordance with the following formats. O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 15: Connection Diagram

    Connect the device according to the connection diagram, "Connection diagram", page 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 16 Power LED lights up green, the device is ready for operation. O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 17: Operation

    Device Description) for this device. You can install this within SOPAS ET using the device catalog. The device description file is saved on the device and can be installed there. Alternatively, installation is possible from the SICK website (Internet connection required).
  • Page 18 (right-hand side): O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 19 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 20 The terminal program is started in the main window of SOPAS via the Tools > Terminal menu. O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 21 A description of the telegrams can be found in the Technical Information Telegram List‐ ing RMS3xx publication (English, no. 8021531). 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx...
  • Page 22: Maintenance

    Recommended: At least every 6 months. O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 23: Troubleshooting

    Poor data connection. Repairs Repair work on the device may only be performed by qualified and authorized person‐ nel from SICK AG. Interruptions or modifications to the device by the customer will inval‐ idate any warranty claims against SICK AG. Returns Do not dispatch devices to the SICK Service department without consultation.
  • Page 24: Disposal

    Separate the recyclable materials by type and place them in recycling containers. ■ O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 25: Technical Data

    Typical radar cross section value for a pedestrian Typical radar cross section value for a car 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx...
  • Page 26: Performance

    - 1.5 V DC, I ≤ 100 mA (typical), short-circuit protected, temperature protected) O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 27: Mechanics/Electronics

    In connected state with suitable mating plug or protective cap mounted on the connections 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx...
  • Page 28: Ambient Data

    –40 °C … +85 °C Ambient humidity 0% ... 90%, non-condensing O P E R A T I N G I N S T R U C T I O N S | RMS3xx 8021530/ZZN3/2018-06-14 | SICK Subject to change without notice...
  • Page 29: Accessories

    Accessories and where applicable mounting information can be found online at: • www.sick.com/RMS3xx 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 30: Annex

    12.2 Licenses SICK uses open-source software. This software is licensed by the rights holders using the following licenses among others: the free licenses GNU General Public License (GPL Version2, GPL Version3) and GNU Lesser General Public License (LGPL), the MIT license, zLib license, and the licenses derived from the BSD license.
  • Page 31 ANNEX 8021530/ZZN3/2018-06-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RMS3xx Subject to change without notice...
  • Page 32 Phone +36 1 371 2680 Phone +386 591 78849 E-Mail ertekesites@sick.hu E-Mail office@sick.si India South Africa Phone +91-22-6119 8900 Phone +27 (0)11 472 3733 Further locations at www.sick.com E-Mail info@sick-india.com E-Mail info@sickautomation.co.za SICK AG | Waldkirch | Germany | www.sick.com...

Table of Contents