RAUTOOL A-LIGHT2
mAInTenAnce nOTes
regular inspection:
risk of injury!
Always remove the battery or unplug from the mains before cleaning
and inspection .
- Always keep jaw sets, expanding tools and cylinders clean .
When soiled, clean them with a brush and oil them . Then store the
tool in a dry place .
- Before every use, check the jaw sets, expanding tools and the
A-light2 basic tool for damage or visible wear . Damaged tools must
not be used anymore and should immediately be sent to an authori-
sed service center for repair .
- Make sure that the jaw sets are fully applied across the whole
surface and at a right angle during the compression process, and
the compression sleeve is inserted up to the fitting collar .
- regularly grease the expanding tool tapers . Do not apply grease
to the surface of expander segments! Should excess grease reach
the expander segments, the segments must be thoroughly cleaned
(e .g . cleaning solvent) and then dried .
repairs
risk of accident!
Do not perform any repairs on the tool yourself! repairs should only be
carried out by an authorised service center .
Storage:
never store the tool if wet! Dry the tool and grease it . Then store it in
a dry place .
As a matter of principle, store the tool in its final position (extended
cylinder or jaw sets) to extend its service life .
en