Description Of The Steps - Vetek DGT Technical Manual

Table of Contents

Advertisement

3.2 DESCRIPTION OF THE STEPS

(*) tYPE TYPE OF APPLICATION (§)
One selects the type of application which will be made: scale with independent channels, a scale with dependent
channels (could be digitally equalized) or scale with independent channels simultaneously viewable on the PC.
Instrument connected to 1, 2, 3 or 4 independent scales.
IND.CH.
Instrument connected to a scale with 2, 3, or 4 dependent load cells (could eventually be digitally
DEP.CH
equalized through a specific software procedure).
TRANSM. Independent channel mode which makes it possible to have a simultaneous transmission, through the
serial line, of the values read by each single channel (for further details see section 8.13
"SIMULTANEOUS TRANSMITTER CHANNEL VALUE", USER MAN.REF.)
NOTE: The configuration and the calibration of the instrument are done the same way as with the
independent channel mode.
(!) IND.CH.
(*) With approved instrument the parameter is read-only.
(§) The parameter is not displayed if one has selected the MASTER/SLAVE functioning mode, FmodE >> FunCt >>
MAStr parameter.
F.ModE SCALE FUNCTIONING
• FunCt FUNCTIONING MODE (§)
Unit of measure conversion.
Std
Net weight / gross weight conversion.
ntGS
Input / output weigh.
inout
Once the in / out mode is selected, "tYPE" is displayed for an instant and then one is asked to select with
PRINT the print mode of the acquired data:
- "G.t." gross/tare:
- "1st.2nd" first weigh/second weigh:
- "in.out" input/output:
MAStr
Multiscale Repeater.
By selecting with PRINT this functioning mode, one is asked to enter the number of SLAVES to be used: for
an instant "nuMSL" is displayed; then enter the number (between 01 and 04).
Alibi memory.
ALibi
Single scale repeater.
rEPE
UiSS
Sensitivity times ten.
hLd
Freezing of the weight on the display.
PEAK
Peak detector.
tot o
Horizontal totalizer.
Once the horizontal totaliser functioning mode is selected, one needs to select the type of totalisation: normal
(t.norM), fast (t.FASt) or automatic (Auto).
tot S
Vertical totalizer.
Once the vertical totaliser functioning mode is selected, one needs to select the type of totalisation: normal
(t.norM), fast (t.FASt) or automatic (Auto).
Counting.
Coun
Once the Counting functioning mode is selected, one needs to select the Unit of Measure of the average piece
weight (APW): g / kg / t / Lb, and the sampling interval in seconds (WAit.t).
(!) ntGS
(§) The parameter is not displayed if one has set "trAnSM" in the tYPE parameter.
13
DGT / DGT60 / DGTQ / DGTP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dgt60DgtqDgtp

Table of Contents