13 Technical data
Technical data
Emissions of nitrogen oxides (NO
Domestic hot water parameters
Declared load profile
Daily electricity consumption
Annually electricity consumption
Water heating energy efficiency
Water heating energy efficiency class
Daily fuel consumption
Annual fuel consumption
Gas category and supply pressure
Country
Germany
1
Belgium
France
Italy
United Kingdom
Spain
Austria
Bulgaria
Czech Republic
Croatia
Hungary
Slovakia
Slovenia
Portugal
Greece
Cyprus
Poland
Ireland
Turkey
Switzerland
Malta
Lithuania
Latvia
Denmark
Romania
(1)
Any modifications to the gas valve MUST be performed by a certified representative of the manufacturer. For more
information, contact your dealer.
Installation and operation manual
40
EHY2KOMB28AA
)
49 mg/kWh
X
Gas category
Default setting
II2ELL3P
G20 (20 mbar)
I2E(s)3Pc,
G20 (20 mbar)
I3P
II2Esi3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3+,
G20 (20 mbar)
II2H3P
II2H3P
G20 (20 mbar)
II2HS3P
G25 (25 mbar)
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3+
G20 (20 mbar)
II2H3+
G20 (20 mbar)
II2H3+
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3+
G20 (20 mbar)
II2H3+
G20 (20 mbar)
II2H3+
G20 (20 mbar)
I3P
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
II2H3P
G20 (20 mbar)
XL
0.077 kWh
17 kWh
87%
A
22.61 kWh
4975 kWh
After conversion to G25
G25 (25 mbar)
G25 (25 mbar)
G25 (25 mbar)
Daikin Altherma hybrid monobloc – Gas boiler module
EHY2KOMB32AA
53 mg/kWh
0.073 kWh
16 kWh
22.51 kWh
4952 kWh
After conversion to G31
G31 (28~50 mbar)
G31 (30 mbar)
G31 (30 mbar)
G31 (30 mbar)
G31 (30~37 mbar)
G31 (30~37 mbar)
G31 (30~50 mbar)
G31 (30 mbar)
G31 (37 mbar)
G31 (30 mbar)
G31 (30 mbar)
G31 (30~50 mbar)
G31 (37 mbar)
G31 (37 mbar)
G31 (37 mbar)
G31 (37 mbar)
G31 (37 mbar)
G31 (37 mbar)
G31 (37 mbar)
G31 (37 mbar)
G31 (30 mbar)
G31 (30 mbar)
G31 (30 mbar)
G31 (30 mbar)
G31 (30 mbar)
EHY2KOMB28+32AA
4P538953-1 – 2018.06