Daikin Altherma EHY2KOMB28AA Installation And Operation Manual page 26

Hybrid monobloc – gas boiler module
Hide thumbs Also See for Altherma EHY2KOMB28AA:
Table of Contents

Advertisement

7 Configuration
Parameter
Setting
Maximum space heating power set
.
Maximum capacity space heating
pump
Maximum domestic hot water power
set
(not applicable for Switzerland)
Minimum supply temperature of the
heat curve
.
Maximum supply temperature of the
heat curve
Minimum outside temperature of the
heat curve
Maximum outside temperature of the
heat curve
Space heating pump post purge period 0~15 min
Space heating pump post purge period
after domestic hot water operation
Position 3-way valve or electric valve
Booster
Step modulation
Minimal space heating rpm
.
Minimum capacity space heating pump —
Minimal domestic hot water rpm
(not applicable for Switzerland)
.
Reversible setting
Start rpm space heating
.
Start rpm domestic hot water
(not applicable for Switzerland)
Installation and operation manual
26
Range
Default
settings
~85%
60%
80
~100%
100%
10°C~25°C
25°C
30°C~90°C
90°C
–30°C~10°C
–7°C
15°C~30°C
25°C
0 min
0~15 min
0 min
0~3
0
0~1
0
0~1
1
23%~50%
30%
40
23%~50%
25%
0~1
0
50%~99%
50%
50%~99%
50%
Description
Maximum power in heating. This is a
percentage of the maximum set in
parameter . We strongly recommend
not modifying this setting.
The setting is controlled by the heat
pump.
Maximum power in instant domestic
hot water. This is a percentage of the
maximum set in parameter . Because
of the 2-digit display, the highest
displayable value is 99. It is however
possible to set this parameter to 100%
(default setting). We strongly
recommend not modifying this setting.
Do NOT modify this setting on the
boiler. Use the user interface instead.
Do NOT modify this setting on the
boiler. Use the user interface instead.
Do NOT modify this setting on the
boiler. Use the user interface instead.
Do NOT modify this setting on the
boiler. Use the user interface instead.
Changing this setting has no effect on
the operation of the unit.
Changing this setting has no effect on
the operation of the unit.
▪ 0=Not inverted
▪ 1=Inverted
▪ 2 and higher=Not applicable
Changing this setting has no effect on
the operation of the unit.
▪ 0=OFF
during
space
operation
▪ 1=ON
during
space
operation
It is recommended not to modify this
setting.
Adjustment range 23~50%.
It is recommended not to modify this
setting in case of natural gas.
There is no space heating pump in the
gas boiler. Changing this setting has
no effect.
Adjustment range 23~50%
(40=propane).
It is recommended not to modify this
setting in case of natural gas.
This setting activates the keep hot
function of the gas boiler. It is only
used with reversible heat pump models
and should NEVER be deactivated. It
MUST be deactivated for heating only
models (set to 0).
▪ 0=disabled
▪ 1=enabled
This is the fan rpm before heating
ignition. It is recommended not to
modify this setting.
Do not modify this setting.
EHY2KOMB28+32AA
Daikin Altherma hybrid monobloc – Gas boiler module
4P538953-1 – 2018.06
heating
heating

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma ehy2komb32aaAltherma h hybrid ehy2komb28aaAltherma h hybrid ehy2komb32aaAltherma h hybrid ehy2komb-a

Table of Contents