5.7.5.
After using the detergent system, flush through with clean water.
note: Failure to clean properly will cause the injection system to become clogged and inoperable.
warninG: do not leave motor switched on for more than 15 minutes without operating trigger.
9
9 9
if the water pressure drops (e.g. someone else using the same water supply), the washer will
not operate correctly. switch the motor off immediately and wait until the pressure is restored.
5.8.
when washing is completed.
5.8.1.
Switch the power supply off by turning switch to 'Off' position (fig.5) unplug from mains and stow
electric flex, keeping plug dry.
5.8.2.
turn off the water supply tap.
5.8.3.
discharge residual pressure by pressing the trigger until no more water comes out of the nozzle.
warninG! Failure to discharge pressure could result in personal injury.
5.8.4.
disconnect the inlet hose and coil the outlet hose back onto the reel.
5.8.5.
Wipe the machine clean and dry and store in a clean, safe, dry, childproof location.

6. trouBleshootinG

sYmPtoms
motor will not start.
circuit breaker trips or fuse blown.
Water or oil leaking from bottom of pump.
trigger will not move.
unit will not stop when trigger is released.
motor running but pump not building.
maximum pressure or has irregular pressure.
7. MaintenanCe
9 9 warninG! ensure the pressure washer is switched off and unplugged from the mains electrical power supply and turned off at the
9
mains water tap before performing any maintenance tasks.
Check, clean or renew the inlet filter (which is fitted inside the inlet connector,) after every 50 hours of use.
Use only genuine Sealey spares for this machine. Failure to do so could result in personal injury and will invalidate the warranty.
7.1.
nozzles
7.1.1.
ensure that nozzles are kept clean and free of debris. clear the nozzle of any debris. flush the nozzle with water.
7.1.2.
reconnect the nozzle to the lance. ensure that the nozzle connection is tight.
7.2.
water filter.
7.2.1.
The pressure washer is equipped with a water inlet filter to protect the pump. Back flush the filter to clean.
7.2.2.
replace filter and quick connection immediately to prevent any ingress of foreign matter into the pump.
© Jack sealey limited
reAson
1. loose or disconnected plug.
2. Blown fuse.
1. circuit overload.
2. nozzle partially blocked, causing
excessive pressure.
1. A small amount of leakage is normal.
1. Gun safety lock engaged.
1. trigger system not operating properly.
1. Water supply not turned on.
2. unit has been stored in freezing
temperatures.
3. Water inlet filter clogged.
4. Kink in supply hose.
5. nozzle worn out.
6. Air in pump.
7. Suction or discharge valves clogged or
worn out.
Original Language Version
fig.8
fig.9
remedY
1. reconnect plug.
2. see below
1. check that the circuit is rated 13amps or
greater. disconnect all loads on the circuit.
2. clean nozzle as described in maintenance
section.
1. if excessive leaking occurs contact
authorised service agent.
1. release safety lock.
1. contact authorised service agent.
1. turn on water supply.
2. thaw out unit completely including hose,
gun and attachments.
3. clean screen as described in maintenance
section.
4. Straighten hose.
5. replace nozzle.
6. Let pressure washer run with gun open
and lance removed until a steady stream
of water is released.
7. Contact authorised service agent.