  • Page 2 1. INTRODUCTION Thank you very much for using Panasonic products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference. 2. CAUTIONS POWER SUPPLY z Periodically check voltage fluctuation to ensure that it does not exceed the rated voltage.
  • Page 3: Functional Description

    3. FUNCTIONAL DESCRIPTION S-LINK system terminal block Connect the signal cable and power supply of the S-LINK system. The S-LINK system terminal block is connector type and it is possible to wire it after removing it from SL-PCAT. - 2 -...
  • Page 4 Terminal Wire color Black Maincable White For loop wiring Blue Brown Black Maincable White Blue Brown Terminal block: MSTB2.5/10-ST-5.08 External power Input (Made by Phoenix Contact) supply input Notes: 1) Do not connect anything at Side B when you do not employ loop wiring. 2) Small type flathead screwdriver (blade size: 0.6mm 3.5mm) is required for the wiring operation.
  • Page 5: Mode Switch

    Mode switch Perform setting of the S-LINK system. I/O SET 0 to 3 are for setting input / output. SA 0 and SA 1 are for setting the number of input / output points. Setting is read in only once when power is supplied to PC/AT. Changing the mode switch setting during operation is ineffective.
  • Page 6 4. ASSIGNMENT OF PC/AT PERSONAL COMPUTER The detection of abnormal S-LINK I/O devices during error occurrence on S-LINK system, connected device No., etc., is assigned in the I/O space of the PC/AT personal computer. [Assignment] PC/AT Assigment I/O address Bank change-over response register (HML) 0 S-LINK I/O units SL-PCAT...
  • Page 7 (HML) 0 to (HML) F Relationship between ‘PC/AT I/O address’ and ‘S-LINK unit address’ PC/AT S-LINK I/O unit address I/O address (H) bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 (hexadecimal) (HML) 0 (HML) 1 (HML) 2 (HML) 3...
  • Page 8 (HML+1) 0: Flag It indicates the operation condition of the S-LINK system. Function Confirmation of communication frame completion bit 7 (Output data communication completed with ‘0’ after writing in ‘1’) bit 6 System set (1: Read out condition of S-LINK I/O unit connection) bit 5 Unusable (= 0) bit 4...
  • Page 9 (HML+1) 2: I/O setup of SL-PCAT It sets up or indicates the I/O assignment of SL-PCAT. Immediately after power supply or reset of personal computer PC/AT, it indicates the setup condition of ‘Mode switch’. When setting I/O by programming, put all I/O setting switches to ‘0’: ON and then write in. Assignment S-LINK address 112 to 127 I/O setup (0: Input, 1: Output) S-LINK address 96 to 111 I/O setup (0: Input, 1: Output)
  • Page 10 (HML+1) 8: Number of S-LINK I/O units where ERROR 4 has occurred It indicates the number of S-LINK I/O units where ERROR 4 has occurred. ERROR 4 can be released (‘0’) by supplying power either to the S-LINK system side or to the personal computer PC/AT once again.
  • Page 11 5. PROGRAM EXAMPLE (For MS-DOS Q Basic) [Assignment] I/O address: 0300H to 031FH [Operation] Set addresses 0 to 15 as output and 16 to 127 as input. Put output addresses 0 to 15 ON. Read out ON / OFF condition of addresses 0 to 127, and display with 2 digits in hexadecimal number system, in units of 16 points.
  • Page 12: Specifications

    6. SPECIFICATIONS Notes: 1) S-LINK system side and PC/AT side are isolated. 2) The current consumption is the sum of the max. current supplied to the connected S-LINK I/O devices (D and G lines only) and the current consumption of the S-LINK control board. 3) The current consumption of the load is the sum of the current consumed by the devices (sensors, switches, actuators, etc.) connected to the S-LINK I/O devices.
  • Page 13 7. INTENDED PRODUCTS FOR CE MARKING The models listed under “6. Specifications” come with CE Marking. As for all other models, please contact our office. [Conditions in use for CE conformity] z Be sure to meet condition 1). Furthermore, either condition 2) or 3) should also be met. Conditions 1) Cable length between the main power supply and the controller should be less than 10m.
  • Page 14: Dimensions (Unit: Mm)

    8. DIMENSIONS (Unit: mm) - 13 -...
  • Page 15 I/O access commands. z If you desire to use the library/driver, you may download it free of charge from our website [http://panasonic-electric-works.net/sunx]. z In case you cannot use our internet home page, please contact our sales office.
  • Page 16 (2) Any Products found to be defective must be shipped to Panasonic Industrial Devices SUNX with all shipping costs paid by Purchaser or offered to Panasonic Industrial Devices SUNX for inspection and examination. Upon examination by Panasonic Industrial Devices SUNX, Panasonic Industrial Devices SUNX will, at its sole discretion, repair or replace at no charge, or refund the purchase price of, any Products found to be defective.