Download Print this page

Pentair Keystone Figure 952 NPS 2 Disassembly Instructions page 2

Knife gate valves

Advertisement

Keystone Figure 952 KniFe gate valves
NPS 2 - 24 DiSaSSembly iNStructioNS
non - Rising spindle valves
• Ensure all parts are clean and free of foreign material, particularly the chest area between the
gland and valve bore.
• For optimum leak-free service, gate faces and edges must be smooth, and free of galling or
burring. Repair or replace if excessively worn or damaged.
• Seating faces in valve bore must be smooth and undamaged otherwise leakage is likely to occur.
Replace if necessary.
• Check gland sealing faces on top of valve body. They should be smooth and undamaged. Repair
if necessary.
• Check threads on spindles and bolts - repair/replace if necessary.
• Replace Nyloc nuts if threads are stripped or weakened. These are used as protection against
vibration.
• Check and replace gate guides (11) if necessary.
Removal and disassemBly
1. ensure pipeline is not pressurized and that any hazardous medium is drained away.
2. Large valves need a chain block or crane to assist. If large, heavy cylinders are fitted, they can
be removed first if felt necessary:
• D isconnect actuator air lines and power supplies etc.
• Support actuator, disconnect rod from valve gate, undo bridge bolts or hold down bolts,
remove actuator from valve.
3. Support valve body and remove all flange bolts.
4. Remove valve and gaskets from the pipeline.
• Remove gland box nuts (8) and washers (21, 10). Remove clevis fasteners (13) and washers
(22).
• Remove upright mounting bolts (12) and washers (14) at valve body (1). Remove pillar nut (19)
and washer (9).
5. Withdraw gland box (3) and gate (2) assembly.
6. Remove gate guides (11) from valve body (1).
pentaiR valves & ContRols
www.pentair.com/valves
All Pentair trademarks and logos are owned by Pentair Ltd. All other brand or product names are trademarks or registered marks of their respective owners.
Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice.
Pentair is an equal opportunity employer. © 2012 Pentair ltd. all rights reserved.
12
14
12
11
note:
NPS 10 - 24 F952 non-rising spindle valve illustrated.
19
9
13
22
2
8
21
10
3
20
1
2

Advertisement

loading

This manual is also suitable for:

Keystone figure 952 nps 8Keystone figure 952 nps 10Keystone figure 952 nps 24