Download Print this page
Utility Solutions BREAK-SAFE USBS-15-1-PS Operation Manual

Utility Solutions BREAK-SAFE USBS-15-1-PS Operation Manual

Load break & pick-up tool
Hide thumbs Also See for BREAK-SAFE USBS-15-1-PS:

Advertisement

Quick Links

Load Break & Pick-up Tool
Phone
(828)323-8914
Fax
(828)323-8410
sales@utilitysolutionsinc.com
Email
www.utilitysolutionsinc.com
Web
101 33
Street Drive SE · Hickory, NC 28602
rd
BREAK-SAFE
Operation Manual
B-01031 USBS Manual (12-19-18)
Contents
Components
Applications
Circuit Restrictions
Line and Tool Preparation
Operation
Resistance Test
Periodic Maintenance*
Storage
Warranty
Copyright © 2018 Utility Solutions, Inc.
USBS-15-1-PS
USBS-15-2-PS
USBS-27-1-PS
USBS-27-2-PS
USBS-38-1-PS
USBS-38-2-PS
USBS-46-1-PS
USBS-46-2-PS
Available Options:
H - Hard Case
Second Generation Models Only.
For tools manufactured after
April 2014 and including
the Yellow Safety Lock.
PATENT NO. 6,078,008 Other Patents Pending
®
S - Soft Case
2
3
3
4
5
7
8
8
8

Advertisement

loading

Summary of Contents for Utility Solutions BREAK-SAFE USBS-15-1-PS

  • Page 1 B-01031 USBS Manual (12-19-18) Contents Components Applications Circuit Restrictions Line and Tool Preparation Operation Resistance Test Periodic Maintenance* Storage Warranty Copyright © 2018 Utility Solutions, Inc. Phone (828)323-8914 (828)323-8410 sales@utilitysolutionsinc.com Email www.utilitysolutionsinc.com 101 33 Street Drive SE · Hickory, NC 28602...
  • Page 2 Components Floating Head Duckbill Head Conductor Hook Yellow Internal Safety Yellow Tube Lock Brass Contacts Load Pick-up Trigger (located under Lock) Conductor Bar Load Break Ring (should rotate freely) B-01031 USBS Manual (12-19-18)
  • Page 3 Applications The BREAK-SAFE is a jumper clamp that functions like a portable switch. It is designed ® to operate on overhead distribution power lines in conjunction with an appropriately rated and approved jumper cable. There are three operating functions: load break, load pick-up and continuous current duty.
  • Page 4 The BREAK-SAFE has been tested to the full voltage and amperage rating for nominal ® power factors of 70%-80% for both load break and load make applications. However, the tool is rated by system voltages. For example, a 15 kV tool on a 15 kV system will usually experience voltages of 15 kV / √3 or about 8.6 kV.
  • Page 5 Operation Prepare the Tool for use Refer to the laminated Field Inspection Procedure card before each use. Place the BREAK-SAFE in the UNLOCK Position (FIGURE 1) by lifting the Yellow ® Safety Lock to gain access to the Load Break Ring. Pull the Load Break Ring until the tool locks in the open tool position (the internal yellow tube is visible).
  • Page 6 18. If the SOURCE SIDE circuit is to remain energized while work is done, move the jumper cable to the conductor bar of a Utility Solutions Jumper-T (USJT-001/2) or equivalent device (FIGURE 7). This will create a visible gap using rated insulation.
  • Page 7 This test DOES NOT replace scheduled maintenance or extend the time between scheduled maintenance. This test is performed using the Utility Solutions USGT-600 Grounds Tester w/ REACH Technology or equivalent device. Refer to the testers’ instruction manual for proper set- up procedures.
  • Page 8 Load Break & Pick-up Tool for any defects ® in manufacturing for the period of one year. If the tool is returned within that time period, Utility Solutions will repair or replace the tool free of charge. B-01031 USBS Manual (12-19-18)

This manual is also suitable for:

Break-safe usbs-15-2-psBreak-safe usbs-27-1-psBreak-safe usbs-27-2-psBreak-safe usbs-38-2-psBreak-safe usbs-38-1-psBreak-safe usbs-46-1-ps ... Show all